CHICAGO, IL —
OSHA Inspection: WINDOW TO THE WORLD COMMUNICATIONS, INC., DBA WTTW CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WINDOW TO THE WORLD COMMUNICATIONS, INC., DBA WTTW CO. in 5400 N. ST. LOUIS, CHICAGO, IL 60625 (NAICS 515120). OSHA activity number 341122455.
Where did this inspection happen?
- Site address
- 5400 N. ST. LOUIS
- City
- CHICAGO
- State
- IL
- ZIP
- 60625
- Mailing
- 5400 N. ST. LOUIS, CHICAGO, IL 60625
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 515120
- Employees
- 190
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.28 D07
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.28(d)(7): Guardrails were not less than 2 x 4 inches or the equivalent and not less than 36 inches or more than 42 inches high, with a mid-rail, as required, of 1- x 4-inch lumber or equivalent, and toeboards, were not installed at all open sides on all scaffolds more than 10 feet above the ground or floor. a) Sound Stage Studio D- On December 10, 2015, the employer failed to ensure that all tubular welded frame scaffolding that was at a height of ten feet or more above the ground or floor, such as Spotlight 1, Spotlight 2, Spotlight 3 and Northeast and Southeast Camera Stations, were equipped with guardrails. b) Sound Stage Studio D- On December 10, 2015, the employer failed to ensure that all tubular welded frame scaffolding that was at a height of ten feet or more above the ground or floor, such as Spotlight 1, Spotlight 2, Spotlight 3 and Northeast and Southeast Camera Stations, was equipped with midrails. c) Sound Stage Studio D- On December 10, 2015, the employer failed to ensure that all tubular welded frame scaffolding that was at a height of ten feet or more above the ground or floor, such as Spotlight 1, Spotlight 2, Spotlight 3 and Northeast and Southeast Camera Stations, was equipped with toeboards on all open sides. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $6300
More inspections in this industry (NAICS 515120)
PORTAGE, MI—2026-05-26 00:00:00
WSMH, INC.
SALT LAKE CITY, UT—2026-05-01 00:00:00
ABC 4 UTAH
OCEAN SHORES, WA—2026-04-23 00:00:00
WA317990952 - INTERNATIONAL TELEVISION GROUP INC
NORTH CHARLESTON, SC—2026-03-26 00:00:00
77389 - WTAT CHARLESTON FOX 24
ROANOKE, VA—2026-03-24 00:00:00
BLUE RIDGE PUBLIC TELEVISION, INC. DBA BLUE RIDGE PBS
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341122455.