Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GRIFFIN FAST LUBE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GRIFFIN FAST LUBE LLC in 6630 CAMDEN BLVD, FOUNTAIN, CO 80817 (NAICS 811191). OSHA activity number 341128247.

Watch Griffin Fast Lube LLC — free Get an email when a new federal OSHA severe-injury report for Griffin Fast Lube LLC is published. One employer, no account, unsubscribe in one click.
Site address
6630 CAMDEN BLVD
City
FOUNTAIN
State
CO
ZIP
80817
Mailing
1725 E 1450 S, STE 250, CLEARFIELD, UT 84015
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.22 C

Repeat Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $8000.00 · Current $4800.00 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc:    a)  On or about December 17, 2015, and at times prior, employees were exposed to fall hazards where the nets in the oil change pits were in disrepair.  The nets installed in the three pits had broken and unraveling netting.       Griffin Fast Lube LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.22(c), which was contained in OSHA inspection number 1020651, citation  number 1, item number 1 and was affirmed as a final order on March 2, 2015, with respect to a workplace located at Jiffy Lube Service Center #705, 5805 Independence St., Arvada, CO, 80002.
Recent events (2)
  • — I (R) $4800
  • — Z (R) $8000

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) On or about December 17, 2015, employees were exposed to electrical hazards where, in the outer service bay, items were stored in front of electrical panels, thereby not maintained a three foot clearance in front of the panels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View GRIFFIN FAST LUBE LLC's full OSHA safety record →