Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEW ENGLAND INSPECTION, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of NEW ENGLAND INSPECTION, INC. in ONE WALLACE AVENUE, SOUTH PORTLAND, ME 04106 (NAICS 332312). OSHA activity number 341157238.

Watch NEW England Inspection, INC. — free Get an email when a new federal OSHA severe-injury report for NEW England Inspection, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ONE WALLACE AVENUE
City
SOUTH PORTLAND
State
ME
ZIP
04106
Mailing
105 OTIS ALLEN ROAD, SANFORD, ME 04073
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.107 C06

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1820.00 Reduced
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:    Paint Area, West Wall - Wall mounted electrical outlets, a circuit breaker panel, light switches, junction boxes, and electrical wiring, as close as 6.9 feet from the flammable and combustible liquids spray area, produced sparks under normal operating conditions and did not conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
Recent events (2)
  • — I (S) $1820
  • — Z (S) $2800

1910.178 L01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1300.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    Establishment - The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2000

1910.178 Q07

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service:    Establishment - The powered industrial truck was not examined at least daily before being place in service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that might have exposed an employee to injury, and the defective or damaged item was not removed from service:    Painting Area, West Wall - The sheathing on the flexible electrical cord of the recycler was severely deteriorated, exposing the insulated conductors.  The recycler was plugged into a 120 volt electrical outlet.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341157238.