Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MCCON BUILDING AND PETROLEUM SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MCCON BUILDING AND PETROLEUM SERVICES, INC. in 1814 GUADALUPE STREET, AUSTIN, TX 78701 (NAICS 237120). OSHA activity number 341163715.

Watch Mccon Building AND Petroleum Services, INC. — free Get an email when a new federal OSHA severe-injury report for Mccon Building AND Petroleum Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1814 GUADALUPE STREET
City
AUSTIN
State
TX
ZIP
78701
Mailing
8120 JETSTAR DRIVE, STE 150, IRVING, TX 75063
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
22
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.  On or about 7 January 2016, and at times prior thereto, an employee was working while inside an excavation without the use of a hard hat, exposing the employee to the hazard of being struck by falling tools, excavated materials, debris, or loose soil and rocks from the excavated wall. At the ladder access in and out of the excavation, cracks and fissures were noted at the time of the inspection.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.251 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.251(b)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and manufacturer.  On or about 7 January 2016, and at times prior thereto, the employer used alloy steel slings without knowing the capacity of the slings to lower a Caterpillar Skid Steer Loader into an excavation without having identification affixed indicating the size, grade, rated capacity, and manufacturer, exposing employees nearby to the hazard of being struck by flying pieces from the sling or a whiplash effect.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.651 C02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.  On or about 7 January 2016, and at times prior thereto, two employees working within an excavation did not have at least two ladders for safe means of egress while the excavation was approximately 32 feet by 38 feet in size, exposing the employees to the hazard of being caught within the excavation during a cave-in event.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.651 I03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures.  On or about 7 January 2016, and at times prior thereto, two employees involved with excavation operations would traverse over pavement in which undermining had occurred without a means of a support system, exposing the employees to a fall hazard of approximately 14 feet 1 inch to the bottom of the excavation.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c).  On or about 7 January 2016, and at times prior thereto, two employees were working in an excavation approximately 14 feet deep without a protective system in place, exposing them to a cave-in hazard.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.651 J01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face.  On or about 7 January 2016, and at times prior thereto, two employees performing work within an excavation would access areas near or adjacent to the excavation wall without a fall-in support system to prevent loose materials falling off the wall face, exposing the employees to the hazard of being struck by falling soil, rocks, and base materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0