SAFFORD, AZ —
OSHA Inspection: BLM,GILA DISTRICT-SAFFORD FIELD OFFICE
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BLM,GILA DISTRICT-SAFFORD FIELD OFFICE in 711 S. 14TH AVENUE, SAFFORD, AZ 85546 (NAICS 924120). OSHA activity number 341182640.
Where did this inspection happen?
- Establishment
- BLM,GILA DISTRICT-SAFFORD FIELD OFFICE
- Site address
- 711 S. 14TH AVENUE
- City
- SAFFORD
- State
- AZ
- ZIP
- 85546
- Mailing
- 711 S. 14TH AVENUE, SAFFORD, AZ 85546
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 70
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.37 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route: (a) Fire Bay: On or about January 15, 2016, emergency lighting was not installed to illuminate the exit route. (b) Force Account, N/E Corner: On or about January 15, 2016, emergency lighting did not function to illuminate the exit route. (c) Warehouse: On or about January 15, 2016, emergency lighting did not function to illuminate the exit route.
Recent events (1)
- — Z (S) $0
1910.106 D02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids: (a) Fire Bay, Cache Area: On or about January 15, 2016, gasoline was stored in unapproved two-compartment fuel/oil (dolmar-style) propylene containers. The standard specification of this container (ANSI/ASTM F285) is not a recognized test standard and the test laboratory (TSG) was not a Nationally Recognized Testing Laboratory (NRTL).
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and automatic start up: (a) Force Account: On or about January 15, 2016, the chuck on the Jet JDM-18 milling/drilling machine, Ser. # 6023452, was not guarded to protect employees from exposure to the rotating chuck. The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 1, item number 3 and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
- — Z (R) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Force Account: On or about January 15, 2016, the distance between the periphery of the abrasive wheel and the tongue guard on the Dayton 1Z707 bench grinder was approximately 1-1/2 inch. The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 1, item number 4B and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
- — Z (R) $0
1910.303 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Fishery biologist's work area: On or about January 15, 2016, a 1500 watt Holmes heater was plugged into a relocatable power tap (RPT). The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085869, citation number 2, item number 2 and was affirmed as a final order on November 3, 2015, with respect to a workplace located at Kingman Field Office, Kingman, AZ.
Recent events (1)
- — Z (R) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Fire Ecologist's desk area: On or about January 15, 2016, the molded plug was separated from the outer insulation of the flexible cord connected to the relocatable power tap. The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 2, item number 1 and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
- — Z (R) $0
1910.1200 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: (a) Warehouse, 2nd storage row, left side, bottom shelf: On or about January 15, 2016, a spray bottle containing an unknown liquid was not labeled. The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1086137, citation number 1, item number 1 and was affirmed as a final order on November 16, 2015, with respect to a workplace located at the Kingman Field Office, Kingman, AZ.
Recent events (1)
- — Z (R) $0
More inspections in this industry (NAICS 924120)
SWEETWATER, TN—2026-07-09 00:00:00
SWEETWATER - PARKS AND RECREATION
EDGEWATER, MD—2026-07-08 00:00:00
ANNE ARUNDEL COUNTY, MARYLAND
COEUR D ALENE, ID—2026-06-24 00:00:00
DEPT. OF AGRICULTURE ? FS-IDAHO PANHANDLE NATIONAL FORESTS
YUMA, AZ—2026-06-22 00:00:00
DEPT. OF INTERIOR - BOR
PORT TOWNSEND, WA—2026-06-22 00:00:00
WA317991484 - WA ST PARKS & RECREATION COMMISSION
More inspections in AZ
CHANDLER, AZ—2026-07-16 00:00:00
SUN STATE BUILDERS
CHANDLER, AZ—2026-07-16 00:00:00
PREMIER UNDERGROUND CONSTRUCTION LLC
PHOENIX, AZ—2026-07-15 00:00:00
CPX2026XTP177X0013 - HZ OPS HOLDINGS, INC.. DBA POPEYES LOUISIANA KITCHEN, INC.
CAMP VERDE, AZ—2026-07-14 00:00:00
CLIFF CASTLE CASINO & HOTEL
CAMP VERDE, AZ—2026-07-14 00:00:00
CLIFF CASTLE CASINO & HOTEL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341182640.