Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BLM,GILA DISTRICT-SAFFORD FIELD OFFICE

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BLM,GILA DISTRICT-SAFFORD FIELD OFFICE in 711 S. 14TH AVENUE, SAFFORD, AZ 85546 (NAICS 924120). OSHA activity number 341182640.

Watch Blm,Gila District-Safford Field Office — free Get an email when a new federal OSHA severe-injury report for Blm,Gila District-Safford Field Office is published. One employer, no account, unsubscribe in one click.
Site address
711 S. 14TH AVENUE
City
SAFFORD
State
AZ
ZIP
85546
Mailing
711 S. 14TH AVENUE, SAFFORD, AZ 85546
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
70
Ownership type
D

7 citations on file for this inspection.

1910.37 B01

Serious Gravity 1 1 instance 45 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route:  (a) Fire Bay: On or about January 15, 2016, emergency lighting was not installed to illuminate the exit route.  (b) Force Account, N/E Corner: On or about January 15, 2016, emergency lighting did not function to illuminate the exit route.  (c) Warehouse: On or about January 15, 2016, emergency lighting did not function to illuminate the exit route.
Recent events (1)
  • — Z (S) $0

1910.106 D02 I

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids:  (a) Fire Bay, Cache Area: On or about January 15, 2016, gasoline was stored in unapproved two-compartment fuel/oil (dolmar-style) propylene containers. The standard specification of this container (ANSI/ASTM F285) is not a recognized test standard and the test laboratory (TSG) was not a Nationally Recognized Testing Laboratory (NRTL).
Recent events (1)
  • — Z (S) $0

1910.212 A01

Repeat Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and automatic start up:  (a) Force Account: On or about January 15, 2016, the chuck on the Jet JDM-18 milling/drilling machine, Ser. # 6023452, was not guarded to protect employees from exposure to the rotating chuck.   The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 1, item number 3 and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
  • — Z (R) $0

1910.215 B09

Repeat Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Force Account: On or about January 15, 2016, the distance between the periphery of the abrasive wheel and the tongue guard on the Dayton 1Z707 bench grinder was approximately 1-1/2 inch.   The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 1, item number 4B and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
  • — Z (R) $0

1910.303 B02

Repeat Gravity 10 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Fishery biologist's work area: On or about January 15, 2016, a 1500 watt Holmes heater was plugged into a relocatable power tap (RPT).   The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085869, citation number 2, item number 2 and was affirmed as a final order on November 3, 2015, with respect to a workplace located at Kingman Field Office, Kingman, AZ.
Recent events (1)
  • — Z (R) $0

1910.305 G02 III

Repeat 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Fire Ecologist's desk area: On or about January 15, 2016, the molded plug was separated from the outer insulation of the flexible cord connected to the relocatable power tap.  The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1085587, citation number 2, item number 1 and was affirmed as a final order on October 23, 2015, with respect to a workplace located at Partner's Point, Lake Havasu, AZ.
Recent events (1)
  • — Z (R) $0

1910.1200 F06

Repeat 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  (a) Warehouse, 2nd storage row, left side, bottom shelf: On or about January 15, 2016, a spray bottle containing an unknown liquid was not labeled.   The Bureau of Land Management was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1086137, citation number 1, item number 1 and was affirmed as a final order on November 16, 2015, with respect to a workplace located at the Kingman Field Office, Kingman, AZ.
Recent events (1)
  • — Z (R) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341182640.