Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LARK UNITED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LARK UNITED in 2290 MCGUFFEY RD., MC GREGOR, TX 76657 (NAICS 336214). OSHA activity number 341185668.

Watch Lark United — free Get an email when a new federal OSHA severe-injury report for Lark United is published. One employer, no account, unsubscribe in one click.
Establishment
LARK UNITED
Site address
2290 MCGUFFEY RD.
City
MC GREGOR
State
TX
ZIP
76657
Mailing
2290 MCGUFFEY RD., MC GREGOR, TX 76657
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336214
Employees
91
Ownership type
A

4 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1607.00 · Current $963.00 Reduced
29 CFR 1910.253(b)(2)(ii):   Cylinders were not stored in areas to ensure that the cylinders would not be knocked over.       In the welding room area, the employer did not secure or store the compressed oxygen cylinder where it would not be knocked over exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $963
  • — Z (S) $1607

1910.305 B02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.   In the welding frame shop, employees use an electrical outlet without the cover plate being secured exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.305 G02 II

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap.   In the production area, the employer spliced the DeWalt drill power cord into another power cord exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1904.29 A

Other-than-serious 1 instance 99 exposed
Issued
Abate by
Penalty
Initial $700.00 · Current $420.00 Reduced
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent:  At the facility located in Lewisville, Texas, the employer did not create, certify, or post an annual summary OSHA 300A and did not maintain 300 logs for each year:      a) 2012     b) 2013     c) 2014
Recent events (2)
  • — I (O) $420
  • — Z (O) $700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341185668.