Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HORIZON WINDOW INSTALLERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HORIZON WINDOW INSTALLERS, INC. in 1326 SPRUCE STREET, PHILADELPHIA, PA 19107 (NAICS 238150). OSHA activity number 341192631.

Watch Horizon Window Installers, INC. — free Get an email when a new federal OSHA severe-injury report for Horizon Window Installers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1326 SPRUCE STREET
City
PHILADELPHIA
State
PA
ZIP
19107
Mailing
557 THOMAS S. BOYLAND ST, BROOKLYN, NY 11212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards:  a/ Jobsite - The employer did not provide effective information and/or training to each employee in the recognition, evaluation, and control of fall hazards associated with their work activities.  Noted on or about 11/21/15
Recent events (1)
  • — Z (S) $2000

1926.502 D15

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.502(d)(8): Horizontal lifelines were not designed, installed, and used under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintained a safety factor of at least two:  a/ Jobsite - Employees engaged in window installation activities working greater than 6 feet from the ground were exposed to fall hazards in that the anchorage point of a horizontal lifeline system was not installed to ensure the safe operation of the fall protection system(s):  1) 29th floor - 30th floor - A synthetic lanyard was looped around a stairway railing while connected to a rope by latch type hook and used as the anchorage point in the horizontal lifeline system.   2) 30th floor - The Sentry Self Retracting (SRL) Lifeline was not installed in accordance with the manufacturer's installation instructions. The SRL was attached to a shock absorbing lanyard that was looped around a stairway railing and used as the anchorage point in the horizontal lifeline system.   Condition observed on or about 1/21/15.
Recent events (1)
  • — Z (S) $2800

1926.502 D21

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  a Jobsite - a synthetic lanyard that contained incomplete stitching was used as an anchorage point, exposing employees to a fall greater than 6 feet.  Observed on or about January 21, 2016
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341192631.