2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ENITOR ENTERPRISES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENITOR ENTERPRISES in 1650 E COUNTY LINE RD, HIGHLANDS RANCH, CO 80126 (NAICS 811191). OSHA activity number 341310043.

Watch Enitor Enterprises — free Get an email when a new federal OSHA severe-injury report for Enitor Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
ENITOR ENTERPRISES
Site address
1650 E COUNTY LINE RD
City
HIGHLANDS RANCH
State
CO
ZIP
80126
Mailing
3703 TIMBERLINE RD, FORT COLLINS, CO 80525
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
7
Ownership type
A

5 citations on file for this inspection.

1910.22 C

Serious Gravity 5 3 instances 7 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc:  a)  On or about March 8, 2016, and at times prior, employees were exposed to fall hazards where the nets in the oil change pits were in disrepair.  The nets installed in the three pits had broken and unraveling netting.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 B02 I

Serious Gravity 5 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a)  On or about March 8, 2016, and times prior, employees were exposed to injuries from exposed live electrical parts, created by an uncovered opening on an electrical box located in the storage area.  (b)  On or about March 8, 2016, and times prior, employees were exposed to injuries from exposed live electrical parts, created by an uncovered opening on an electrical box located near the heater in the basement.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.106 E09 III

Other-than-serious 4 instances 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  (a)  On or about March 8, 2016, and at times prior, the employer exposed employees to fire hazards in that the metal receptacles, located in the oil pit area, were lined with a plastic bag and contained combustible oily rags which were not covered and/or disposed of on a daily basis.  Additionally, oily rags located in the automotive bay area were kept in a plastic bucket rather than a covered metal receptacle.                                                                               Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a)  On or about March 8, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the automotive bay and pit area, had not been inspected since 2013.   Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a)  On or about March 8, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the automotive bay area, had not been inspected since 2013.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ENITOR ENTERPRISES's full OSHA safety record →