APPLETON, WI —
OSHA Inspection: NORTHEAST WISCONSIN PRINTING CO., INC..
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHEAST WISCONSIN PRINTING CO., INC.. in 1718 EAST WISCONSIN AVE, APPLETON, WI 54911 (NAICS 323111). OSHA activity number 341320752.
Where did this inspection happen?
- Establishment
- NORTHEAST WISCONSIN PRINTING CO., INC..
- Site address
- 1718 EAST WISCONSIN AVE
- City
- APPLETON
- State
- WI
- ZIP
- 54911
- Mailing
- 1718 E. WISCONSIN AVE, APPLETON, WI 54911
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 35
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 3/14/2016, the employer was not conducting periodic inspections of their energy control procedures.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 3/14/2016, the company was using electrical outlet boxes designed to be wall mounted for use with flexible wiring as extension cables.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) On or about 3/14/2016, secondary containers for chemicals like hydraulic oil were available for use without workplace labeling as required in the maintenance area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323111)
NASHVILLE, TN—2026-07-16 00:00:00
SOMETHING INKED
MIDDLE RIVER, MD—2026-07-13 00:00:00
MANN-PAK
MUSKEGON, MI—2026-07-08 00:00:00
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02 00:00:00
INNOTECH LASER
HERMITAGE, PA—2026-07-01 00:00:00
CCL CONTAINER, INC.
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341320752.