OSHA Inspection: BIJOL AND SPICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BIJOL AND SPICES INC. in 2154 NW 22ND CT, MIAMI, FL 33142 (NAICS 311942). OSHA activity number 341418614.

Watch Bijol AND Spices INC. — free Get an email when a new federal OSHA severe-injury report for Bijol AND Spices INC. is published. One employer, no account, unsubscribe in one click.
Site address
2154 NW 22ND CT
City
MIAMI
State
FL
ZIP
33142
Mailing
2154 NW 22ND CT, MIAMI, FL 33142
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311942
Employees
4
Ownership type
A

15 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed a fall hazard:      On or about May 25, 2016, at the packaging area of the above addressed jobsite, an employee was exposed to a fall hazard while raised on a wood pallet lacking guardrails or fall protection, which was not secured to the forks and/or mast of a powered industrial truck.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.      On or about April 21, 2016, at the preparation room of the above addressed jobsite, employees worked in an area that had Class II combustible dust deposited on electrical conduits, electrical equipment, ceiling joists and masonry walls.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.157 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:      On or about May 25, 2016, at the above addressed jobsite, the employer had not provided employees with training on the use of fire extinguishers.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.178 C02 VI A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.178(c)(2)(vi)(a): The employer did not provide powered industrial trucks designated as EX for use in an atmosphere in which combustible dust is or may be in suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced.      On or about April 21, 2016, at the preparation room of the above addressed jobsite, a LP-type powered industrial truck (i.e. DAEWOO, Serial #06-02662) was used in an area where combustible dust was generated as part of the production process, exposing employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.219 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:      On or about May 25, 2016, at the preparation room of above addressed jobsite, an employee was exposed to a caught by hazard while working in the proximity of an unguarded shaft located at 12 inches from floor level, which was not guarded.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about May 25, 2016, at the preparation room of above addressed jobsite, employees were exposed to a caught by hazard while working in the proximity of an unguarded belt and pulley assembly located within 41-47 inches from floor level, which was not guarded.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   On or about May 25, 2016, at the preparation room of above addressed jobsite, employees were exposed to a caught by hazard while working in the proximity of an unguarded belt and pulley assembly located within 41-47 inches from floor level, which was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     On or about April 21, 2016, at the packaging room of the above addressed jobsite, employees were exposed to a struck by hazard while using compressed air for cleaning purposes at 70 psi.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:      On or about May 25, 2016, at the preparation room of the above addressed jobsite, electrical conductors entering into a junction box were not protected from abrasion, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.   On or about May 25, 2016, at the above addressed jobsite.   a.  At the preparation room, an electrical junction box had an unused opening which was not covered, exposing employees to a fire hazard.     b.  At the packaging area, an electrical junction box had two unused openings which were not covered, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:      On or about May 25, 2016, at the kitchen area of the above addressed jobsite, an electrical outlet lacked a cover plate, exposing an employee to an electrical hazard.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.307 C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:      On or about April 21, 2016, at the preparation room of the above addressed jobsite, employees worked in an Class II, Division 1 location, where electrical equipment installed including, but not limited to, motor fans, electrical outlet boxes, disconnect switches, breaker panels, were not intrinsically safe, approved for a Class II, Division 1 location or safe for a Class II Division 1 location.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  On or about May 25, 2016, at the packaging area of the above addressed jobsite, drums of finished product (i.e. Bijol seasoning, weighting 125 lbs each) were stored on a mezzanine without having load limits posted, exposing employees to a struck by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.36 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(b)(1): At least two exit routes were not available in the workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route.   On or about May 25, 2016, at the warehouse area of the above addressed jobsite,  employees were exposed to a fire hazard while working in an area with only two exit doors towards the front of the building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  On or about May 25, 2016, at the packaging area of above addressed jobsite, a printer lacked strain relief where its cord entered into the attachment plug, exposing an employee to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BIJOL AND SPICES INC.'s full OSHA safety record →

OFI

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341418614.