OSHA Inspection: HUA DA CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HUA DA CONSTRUCTION, INC. in 934 ARCH ST, PHILADELPHIA, PA 19107 (NAICS 236116). OSHA activity number 341432441.

Watch HUA DA Construction, INC. — free Get an email when a new federal OSHA severe-injury report for HUA DA Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
934 ARCH ST
City
PHILADELPHIA
State
PA
ZIP
19107
Mailing
905 ARCH ST, PHILADELPHIA, PA 19107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.350 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3742.00 · Current $3742.00
29 CFR 1926.350(a)(1): Valve protection cap(s) in place were not in place and secured on compressed gas cylinder(s):  a) 934 Arch St, Philadelphia, PA - The employer did not ensure that the valve caps were secured to the compressed gas cylinders when not in use thus exposing the employees to explosion hazards. This condition was observed on or about March 7, 2016.
Recent events (1)
  • — Z (S) $3742

1926.350 A09

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position:  a) 934 Arch St, Philadelphia, PA - The employer did not ensure that the compressed gas cylinders were stored upright and secured thus exposing the employees to explosion hazards. This condition was observed on or about March 7, 2016.
Recent events (1)
  • — Z (S) $0

1926.350 A10

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:  a) 934 Arch St, Philadelphia, PA - The employer did not ensure that an oxygen cylinder was separated from an acetylene cylinder when in storage at a minimum distance of 20 feet thus exposing the employees to an explosion hazard. This condition was observed on or about March 7, 2016.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3741.00 · Current $3741.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level by use of personal fall arrest systems or guardrail systems:  a) 934 Arch St, Philadelphia, PA - The employees were working off of a fabricated frame scaffold which did not have a guardrail system installed on the working levels of the scaffold. This hazard exposed the employees to a fall hazard ranging from approximately 17 to 20 feet. This condition was observed on March 7, 2016.
Recent events (1)
  • — Z (S) $3741

1926.501 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $3741.00
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes, more than six feet above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  a) 934 Arch St, Philadelphia, PA - The employer did not protect the employees from falling through the floor holes with some type of fall protection system thus exposing the employees to fall hazards. This condition was observed on or about March 7, 2016.
Recent events (1)
  • — Z (S) $3741

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $2672.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  a) 934 Arch St, Philadelphia, PA - The portable ladder with broken rails was not tagged and withdrawn from service thus exposing the employees to fall hazards. This condition was observed on or about March 7, 2016.
Recent events (1)
  • — Z (S) $2672