CINNAMINSON, NJ —
OSHA Inspection: LAKEVIEW MEMORIAL PARK
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LAKEVIEW MEMORIAL PARK in 1300 US-130, CINNAMINSON, NJ 08077 (NAICS 812220). OSHA activity number 341439164.
Where did this inspection happen?
- Establishment
- LAKEVIEW MEMORIAL PARK
- Site address
- 1300 US-130
- City
- CINNAMINSON
- State
- NJ
- ZIP
- 08077
- Mailing
- 1300 US-130, CINNAMINSON, NJ 08077
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812220
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ingition may include open flames, lightning, smoking, hot sirfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used portable heaters with open hot flame/heating elements in the vicinity of gasoline cans which were stored inside the maintenance shop, observed on or about 1/20/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used a Baldor bench grinder with tools and equipment which was no completely guarded, observed on or about 1/20/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1910.305 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installations rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (A), (B) and (C) of this paragraph: a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used temporary wiring to power various equipment in the shop and was used to power security and other utility systems, observed on or about 1/20/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1910.305 A02 IX
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees worked with equipment where general lighting installations did not have covers to prevent accidental contact, observed on or about 1/20/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and outlet boxes in completed installations did not have a cover, faceplate, or fixture canopy: a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used switches and worked in the immediate vicinity of junction boxes which did not have covers or faceplates, observed on or about 1/20/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used an extension cord to power various equipment including but not limited to heaters which was damaged in that the conductors were exposed, observed on or about 1/20/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1926.601 B14
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.601(b)(14): All vehicles in use were not checked at the beginning of each shift to assure that the following parts, equipment, and accessories were in safe operating condition and free of apparent damage which could cause failure while in use: service brakes, including trailer brake connections; parking system (hand brake); emergency stopping system (brakes); tires; horn; steering mechanism; coupling devices; seat belts; operating controls; and safety devices. a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees worked with a Case 580M backhoe to excavate and handle materials including but not limited to vaults and coffins where a safety outrigger would not engage due to hydraulic system component failure, observed on or about 1/20/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1926.602 A09 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.602(a)(9)(ii): Earth moving or compacting equipment which had an obstructed view to the rear was operated in reverse gear; such equipment did not have in operation a reverse signal alarm distinguishable from the surrounding noise level or did an employee signalled that it is safe to do so. a) Commercial facility at 1300 US 130 in Cinnaminson, NJ, 08077- Maintenance shop: Employees used a case 580M backhoe with an intermittent reverse signal alarm to dig excavations and handle materials such as but not limited to vaults and coffins, observed on or about 1/20/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 812220)
TACOMA, WA—2026-07-08 00:00:00
WA317992043 - CALVARY CEMETERY
PASO ROBLES, CA—2026-06-25 00:00:00
4283929 DELAWARE LLC
FLORENCE, SC—2026-06-24 00:00:00
U.S. DEPT OF VETERANS AFFAIRS
SAN JUAN, PR—2026-06-18 00:00:00
MUNICIPIO DE SAN JUAN
IGO, CA—2026-06-15 00:00:00
NORTHERN CALIFORNIA VETERANS CEMETERY
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source