Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIE-ARIZONA SOUTH ELO

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BIE-ARIZONA SOUTH ELO in SANTA ROSA DAY SCHOOL RT 15, 44 MILES SOUTH OF CASA GRANDE, SELLS, AZ 85634 (NAICS 561210). OSHA activity number 341451151.

Watch Bie-Arizona South ELO — free Get an email when a new federal OSHA severe-injury report for Bie-Arizona South ELO is published. One employer, no account, unsubscribe in one click.
Site address
SANTA ROSA DAY SCHOOL RT 15, 44 MILES SOUTH OF CASA GRANDE
City
SELLS
State
AZ
ZIP
85634
Mailing
SANTA ROSA DAY SCHOOL HC01, BOX 8400, SELLS, AZ 85634
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
30
Ownership type
D

9 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, gasoline was stored in an unapproved propylene container. The standard specification of this container (ANSI/ASTM F852) is not a recognized test standard under OSHA's Nationally Recognized Testing Laboratory (NRTL) Program.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and automatic start up.  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, the chuck on the Rockwell 15-017 drill press was not guarded to protect employees from exposure to the rotating chuck.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, the Rockwell 15-017 drill press was not anchored to the floor.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Repeat Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, the work rest spacing on the Dayton bench grinder was approximately 1 inch.    The Bureau of Indian Education was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1056018, citation number 1, item number 3 and was affirmed as a final order on November 9, 2015, with respect to the BIE maintenance shop located at Paquolte Dr., Fort Defiance, AZ 86504.
Recent events (1)
  • — Z (R) $0

1910.215 B09

Repeat Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, the tongue guard on the Dayton bench grinder was missing and the opening was approximately 1 inch.   The Bureau of Indian Education was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1056018, citation number 1, item number 4 and was affirmed as a final order on November 9, 2015, with respect to the BIE maintenance shop located at Paquolte Dr., Fort Defiance, AZ 86504.
Recent events (1)
  • — Z (R) $0

1910.303 G02 I

Repeat Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, the dead-front on the circuit breaker panel was removed which exposed employees to an electrical shock hazard.    The Bureau of Indian Education was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1056018, citation number 1, item number 5 and was affirmed as a final order on November 9, 2015, with respect to the BIE maintenance shop located at Paquolte Dr., Fort Defiance, AZ 86504.
Recent events (1)
  • — Z (R) $0

1904.32 A02

Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(2): The employer did not create an annual summary of injuries and illnesses recorded on the OSHA log:  (a) Administrative Office: A site-specific annual summary of injuries and illnesses (OSHA form 300A) was not created for calendar year 2015.
Recent events (1)
  • — Z (O) $0

1910.132 D01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, and at times prior thereto, a hazard assessment was not performed to identify personal protective equipment necessary to protect maintenance workers from eye and hand injuries.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Maintenance Shop, Bldg. 423: On or about May 3, 2016, a written hazard communication program was not developed and implemented for hazardous chemicals such as, but not limited to, spray paints and lubricating oils.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341451151.