2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PINE DOOR

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PINE DOOR in 3225 OLD DARBY RD, DARBY, MT 59829 (NAICS 321911). OSHA activity number 341512457.

Watch Pine Door — free Get an email when a new federal OSHA severe-injury report for Pine Door is published. One employer, no account, unsubscribe in one click.
Establishment
PINE DOOR
Site address
3225 OLD DARBY RD
City
DARBY
State
MT
ZIP
59829
Mailing
PO BOX 178, DARBY, MT 59829
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.213 A09

Serious Gravity 5 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:  a. Rip Saw Area: On or about May 25, 2016, and at times prior, employees were exposed to caught in hazards while operating a Rainman ProfiRip KM 310M Rip Saw without a chain guard in place.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.213 S06

Serious Gravity 1 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  a. Radial Arm Saw Room: On or about May 25, 2016, and at times prior, employees were exposed to fire hazards from accumulations of explosive wood dust on and around a SCMI Radial Arm Saw Model # RS 650.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.303 G01 II

Serious Gravity 1 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a. Band Saw Area: On or about May 25, 2016, and at times prior, employees were exposed to the inability to access an electrical shutoff box due to materials being stored directly in front of the box.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.305 C04

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface.   a. Radial Arm Saw Room: On or about May 25, 2016, and at times prior, employees were using light switches having a cracked faceplate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a. Pine Door: On or about May 25, 2016, and at times prior, employees were working with chemicals including, but not limited to wood glue, high strength epoxy, stains, as well as wood dust in the workplace.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341512457.