Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MERITEX LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MERITEX LLC in 160 CIRCLE DR. NORTH, PISCATAWAY, NJ 08854 (NAICS 333312). OSHA activity number 341623452.

Watch Meritex LLC — free Get an email when a new federal OSHA severe-injury report for Meritex LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MERITEX LLC
Site address
160 CIRCLE DR. NORTH
City
PISCATAWAY
State
NJ
ZIP
08854
Mailing
160 CIRCLE DR. NORTH, PISCATAWAY, NJ 08854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333312
Employees
45
Ownership type
A

2 citations on file for this inspection.

1910.179 J02 IV

Deleted Serious Gravity 10 1 instance 45 exposed
Issued
Abate by
Penalty
Initial $8730.00 · Current $0.00 Reduced
29 CFR 1910.179(j)(2)(iv): A monthly inspection, with certification, was not conducted of Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations.   a/ Meritex LLC, 160 Circle Drive North, Piscataway NJ site. - The Employer did not maintain written certification records of the monthly hoist chain inspection. The monthly certification record to include the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.  Observed on/or about 06/29/2016.
Recent events (3)
  • — J (S) $0
  • — C (S) $8730
  • — Z (S) $8730

1910.212 A03 II

Deleted Serious Gravity 10 1 instance 45 exposed
Issued
Penalty
Initial $8730.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, were not adequately guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a/ Meritex LLC, 160 Circle Drive North, Piscataway NJ site: Elevator #1(Hoist#1)Area. - The access door to the operating overhead conveyor system , caged area was not provided with a lock or chain and did not provide sufficient guarding, exposing employees to a struck by hazard by containers weighing 250lb or more being moved on an automated overhead conveyor system.  Observed on/or about 06/29/2016.
Recent events (3)
  • — J (S) $0
  • — C (S) $8730
  • — Z (S) $8730

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341623452.