Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHEEVER DEVELOPMENT CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHEEVER DEVELOPMENT CORPORATION in 2848 BAINBRIDGE AVENUE, BRONX, NY 10458 (NAICS 238910). OSHA activity number 341697357.

Watch Cheever Development Corporation — free Get an email when a new federal OSHA severe-injury report for Cheever Development Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2848 BAINBRIDGE AVENUE
City
BRONX
State
NY
ZIP
10458
Mailing
SIXTY SACKETT STREET, BROOKLYN, NY 11231
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.25 A

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $4988.00 · Current $3492.00 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:    On or about; July 28, 2016    Location: 2848 Bainbridge Avenue Bronx,  NY 10458, Residential 4 story building, 1st floor, Rooms # 105, 106 and 107     a) Employees engaged in residential building renovation activities at the first floor level were not protected from trip/fall hazards by keeping all work areas clear from scrap lumber with protruding nails, and all other debris.
Recent events (2)
  • — I (S) $3492
  • — Z (S) $4988

1926.403 E

Serious Gravity 10 4 instances 10 exposed
Issued
Penalty
Initial $8730.00 · Current $6111.00 Reduced
29 CFR 1926.403(e): Splices. Conductors were not spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose:    On or about; August 3, 2016    Location: 2848 Bainbridge Avenue Bronx,  NY 10458, Residential 4 story building, 1st, 2nd 3rd and 4th floor levels     a) Employees engaged in residential building renovation activities at the 1st, 2nd 3rd and 4th floor level were exposed to electrical hazards by using temporary wired flexible cords with splices and joints not properly covered with an insulation equivalent.
Recent events (2)
  • — I (S) $6111
  • — Z (S) $8730

1926.405 A02 II I

Serious Gravity 10 2 instances 10 exposed
Issued
Penalty
Initial $8730.00 · Current $6111.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage. Sharp corners and projections were not avoided:    On or about; August 3, 2016    Location: 2848 Bainbridge Avenue Bronx,  NY 10458, Residential 4 story building, 1st floor    a) Employees engaged in residential building renovation activities at the 1st  floor level were exposed to electrical hazards by using temporary wired flexible extension cord unprotected from damage.
Recent events (2)
  • — I (S) $6111
  • — Z (S) $8730

1926.501 B04 II

Serious Gravity 5 3 instances 10 exposed
Issued
Penalty
Initial $4988.00 · Current $3491.00 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes by covers:    On or about; August 3, 2016    Location: 2848 Bainbridge Avenue Bronx,  NY 10458, Residential 4 story building, 1st and 3rd floor levels    a) Employees engaged in residential building renovation activities at the 1st and 3rd floor levels were exposed to tripping in or stepping into or through unprotected holes.
Recent events (2)
  • — I (S) $3491
  • — Z (S) $4988

1926.501 B14

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $8730.00 · Current $6111.00 Reduced
29 CFR 1926.501(b)(14): "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, was not  protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:     On or about; August 3, 2016    Location: 2848 Bainbridge Avenue Bronx,  NY 10458, Residential 4 story building, 4th floor    a) Employees engaged in residential building renovation activities at the 4th floor level working near a wall opening 24inches above the walking/working surface were not protected from falling by the use of a proper guardrail system.
Recent events (2)
  • — I (S) $6111
  • — Z (S) $8730

View CHEEVER DEVELOPMENT CORPORATION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341697357.