Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METROPOLITAN PAINT AND HOME IMPROVEMENT INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of METROPOLITAN PAINT AND HOME IMPROVEMENT INC. in 4715 BUTTERWORTH PLACE NW, WASHINGTON, DC 20016 (NAICS 238170). OSHA activity number 341710317.

Watch Metropolitan Paint AND Home Improvement INC. — free Get an email when a new federal OSHA severe-injury report for Metropolitan Paint AND Home Improvement INC. is published. One employer, no account, unsubscribe in one click.
Site address
4715 BUTTERWORTH PLACE NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
1808 S. OAKLAND STREET, ARLINGTON, VA 22204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $1090.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) On or about August 10, 2016; Rear of residential home; employees were conducting their assigned duties under or near a scaffold system, in which employee was working on, without head protection.         In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1090
  • — Z (S) $2138

1926.102 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1908.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    a) On or about August 10, 2016; Rear of residential home; employees were operating electrical equipment such as but not limited to nail guns and saws without eye protection exposing them to potential injury.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1908
  • — Z (S) $3741

1926.304 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1908.00 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:    a) On or about August 10, 2016; garage area; employees were using a table saw that was not equipped with an adjustable guard.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1908
  • — Z (S) $3741

1926.304 F

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f): Section 3.1.3(c) American National Standards Institute 01.1.1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  In applications  where injury to the operator might result if motors were to restart after power failures, provision were not taken to prevent machines from automatically restarting upon restoration of power:  a) On or about August 10, 2016; Garage area; the table saw used in the process was not equipped with an anti-restart/magnetic switch that would ensure the equipment would not re-start in the event of a power outage and restoration.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $1090.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.    a) On or about August 10, 2016; rear of residential home; employees were operating electrical tools such as but not limited to saws that were not plugged into a ground fault circuit interrupter (GFCI) exposing employees to a potential shock hazard.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1090
  • — Z (S) $2138

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1908.00 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights     a) On or about August 10, 2016; rear of residential home; employees were observed working on the top tier of a scaffold system that was not fully planked exposing them to an estimated fall of 25 feet to ground level. The platform in which the employees were working on only had one plank.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1908
  • — Z (S) $3741

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.   a) On or about August 10, 2016; Rear of the residential home; the employees were using the scaffold braces and frame in place of ladder to access the working platform.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

MACY'S