WASHINGTON, DC —
OSHA Inspection: METROPOLITAN PAINT AND HOME IMPROVEMENT INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of METROPOLITAN PAINT AND HOME IMPROVEMENT INC. in 4715 BUTTERWORTH PLACE NW, WASHINGTON, DC 20016 (NAICS 238170). OSHA activity number 341710317.
Where did this inspection happen?
- Establishment
- METROPOLITAN PAINT AND HOME IMPROVEMENT INC.
- Site address
- 4715 BUTTERWORTH PLACE NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 1808 S. OAKLAND STREET, ARLINGTON, VA 22204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2138.00 · Current $1090.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about August 10, 2016; Rear of residential home; employees were conducting their assigned duties under or near a scaffold system, in which employee was working on, without head protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1090
- — Z (S) $2138
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1908.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) On or about August 10, 2016; Rear of residential home; employees were operating electrical equipment such as but not limited to nail guns and saws without eye protection exposing them to potential injury. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1908
- — Z (S) $3741
1926.304 H01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1908.00 Reduced
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) On or about August 10, 2016; garage area; employees were using a table saw that was not equipped with an adjustable guard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1908
- — Z (S) $3741
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(f): Section 3.1.3(c) American National Standards Institute 01.1.1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): In applications where injury to the operator might result if motors were to restart after power failures, provision were not taken to prevent machines from automatically restarting upon restoration of power: a) On or about August 10, 2016; Garage area; the table saw used in the process was not equipped with an anti-restart/magnetic switch that would ensure the equipment would not re-start in the event of a power outage and restoration. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $2138.00 · Current $1090.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) On or about August 10, 2016; rear of residential home; employees were operating electrical tools such as but not limited to saws that were not plugged into a ground fault circuit interrupter (GFCI) exposing employees to a potential shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1090
- — Z (S) $2138
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1908.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights a) On or about August 10, 2016; rear of residential home; employees were observed working on the top tier of a scaffold system that was not fully planked exposing them to an estimated fall of 25 feet to ground level. The platform in which the employees were working on only had one plank. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1908
- — Z (S) $3741
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about August 10, 2016; Rear of the residential home; the employees were using the scaffold braces and frame in place of ladder to access the working platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
EAST HAVEN, CT—2026-07-16 00:00:00
BIANCO & SONS, LLC
FORT LEE, NJ—2026-07-15 00:00:00
SJM GENERAL CONTRACTORS LLC
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14 00:00:00
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14 00:00:00
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
More inspections in DC
WASHINGTON, DC—2026-06-30 00:00:00
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16 00:00:00
MACY'S
WASHINGTON, DC—2026-06-02 00:00:00
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341710317.