FREDERICKTOWN, MO —
OSHA Inspection: KRANJEC MIDWEST
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KRANJEC MIDWEST in 320 NORTH MINE LA MOTTE, FREDERICKTOWN, MO 63645 (NAICS 311119). OSHA activity number 341717973.
Where did this inspection happen?
- Establishment
- KRANJEC MIDWEST
- Site address
- 320 NORTH MINE LA MOTTE
- City
- FREDERICKTOWN
- State
- MO
- ZIP
- 63645
- Mailing
- 320 NORTH MINE LA MOTTE, FREDERICKTOWN, MO 63645
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311119
- Employees
- 2
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.23 C02
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $1336.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(2): Runways four feet or more above floor or ground level were not guarded by standard railings (or the equivalent): On the top of the feed building, the catwalk from the caged ladder to the platform for greasing the electrical motor bearings, was not guarded by a railing or any other fall protection. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $1336
- — Z (S) $2672
1910.23 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: On the top of the feed building, the platform for greasing the electrical motor bearings, was not guarded by a mid rail. (Note: the platform guard rail must fully enclose the platform, including providing a chain, swinging gate, or some similar method of guarding from the opening of the ladder to the platform.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C04
- Issued
- Abate by
- Penalty
- Initial $1604.00 · Current $802.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: A confined space program, in writing, was not developed and implemented according to the specific requirements as stated at 1910.146(d)(1) through (14), for entry into the feed building bins to free caked grain and product. (Note: A confined space program includes documented training, with all the elements included in the confined space standard, proper tie-off anchors for fall protection used during entry, ensuring the attendant understands his duties to assist in safe entry for the entrant, including how to implement rescue, lockout of equipment during entry, development and completion of the confined space entry permit, and all other requirements of the confined space program. The confined space program must be documented in writing and retraining must be made annually if employee's conduct rescue. If 911 is used for rescue the employer must ensure that the local rescue agency is capable of performing confined space rescue, is able to respond quickly, and has been notified of the employer's reliance on 911 for rescue. In addition the employees, entrant and attendant, must be able to safely access the top of the bin without exposure to a fall.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $802
- — Z (S) $1604
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $1336.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: A lockout program and machine specific procedures, that addressed all of the requirements of the standard, 1910.147, was not fully developed and implemented and was not in writing, for work that included, but was not limited to, the greasing of motor bearings at the top of the feed building where an employee was exposed to an unguarded chain and sprocket, greasing of motor bearings at the top of the fertilizer building where an employee was exposed to an unguarded belt and pulley, and other maintenance activity, such as greasing of other equipment. (Lockout procedures must fully address all of the elements as stated at 1910.147(c)(4)(ii)(A) through (D). Documented training is required, proper hardware must be provided and used, testing of equipment after lock application must be made, and all of the other requirements of the standard must be implemented.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $1336
- — Z (S) $2672
1910.147 C05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Lockout hardware, such as locks and circuit breaker lockout devices, were not provided for lockout of equipment during work such as greasing bearings in the feed and fertilizer buildings. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Training on lockout, according to the specific requirements of the standard, including how and where to lockout, equipment to be used, testing of equipment after a lock is applied, and other standard requirements, was not provided to authorized employees (the employee who applies the lock and performs the work) and affected employees (employees who operate or work around the equipment that could be locked out but do not actually do the lockout work). Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: During work that required lockout such as, but not limited to, the greasing of motor bearings at the top of the feed building where an employee was exposed to an unguarded chain and sprocket, greasing of motor bearings at the top of the fertilizer building where an employee was exposed to an unguarded belt and pulley, and other maintenance activity, such as greasing of other equipment, a lock was not applied. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Disconnects and/or any other energy isolation device for all motors and other equipment that is required to be locked out during work requiring lockout were not marked or legibly marked to show what machine or equipment it energizes. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 311119)
SALT LAKE CITY, UT—2026-06-30 00:00:00
INVE AQUACULTURE INC
CHILLICOTHE, MO—2026-06-30 00:00:00
MILBANK MILLS INC
GREELEY, CO—2026-06-16 00:00:00
GREELEY SEED CO., LLC
HELM, CA—2026-06-15 00:00:00
B&R CUSTOM CHOPPING LLC
LEXINGTON, NE—2026-06-05 00:00:00
LIVESTOCK NUTRITION CENTER
More inspections in MO
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.