Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LAMAR CLEANERS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LAMAR CLEANERS in 9835 S. PULASKI, EVERGREEN PARK, IL 60805 (NAICS 812320). OSHA activity number 341767754.

Watch Lamar Cleaners — free Get an email when a new federal OSHA severe-injury report for Lamar Cleaners is published. One employer, no account, unsubscribe in one click.
Establishment
LAMAR CLEANERS
Site address
9835 S. PULASKI
City
EVERGREEN PARK
State
IL
ZIP
60805
Mailing
9835 S. PULASKI, EVERGREEN PARK, IL 60805
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
10
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  Shop area - On or about September 13, 2016, employees were required to perform servicing on the Unipress shirt sleeves machine, Union washer, and other operating equipment The employer did not establish a written energy control (lockout/tagout) program consisting of energy control procedures, employee training and periodic inspections. The employees were thereby exposed to the hazards associated with the unexpected energization of equipment.
Recent events (1)
  • — Z (S) $0

1910.303 G01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:  Facility east - On or about September 13, 2016, in the facility employees are required to work near and around an electrical panel that was blocked by one 55 gallon barrel, two poles and other materials stored in front of it.   Employees were thereby exposed to hazards associated with blocked electric panels.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:  Facility east - On or about September 13, 2016, the end of a flexible conduit wires coming from an electrical junction box were not completely guarded, thereby employees were exposed to the hazard of contacting electrical conductors.
Recent events (1)
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.  Facility area - On or about September 13, 2016, the passageway was not kept clean and orderly ,in that there were broken and loose floor tiles on the floor, thereby exposing employees to trip and fall hazards.
Recent events (1)
  • — Z (O) $0

1910.141 D02 II

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(ii): Each lavatory shall be provided with hot and cold running water, or tepid running water.  Facility area - On or about September 13, 2016, the employees were not provided hot or tepid running water in the washroom.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:  On or about September 13, 2016, in the facility, employees were required to work with various chemicals including, but not limited to Picrin, DF 2000 Fluid, NDT Sour, and various other chemicals. The employer failed to develop and implement a hazard communication program.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets.  Facility area - On or about September 13, 2016, employees required to work with various chemicals including, but not limited to Picrin, DF 2000 fluid, and NDT Sour had not been trained and provided information on the chemical hazards to which they were exposed to in the workplace.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341767754.