Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PLASTIFORM PACKAGING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PLASTIFORM PACKAGING, INC. in 114 BEACH STREET, BLDG 6, ROCKAWAY, NJ 07866 (NAICS 325211). OSHA activity number 341844496.

Watch Plastiform Packaging, INC. — free Get an email when a new federal OSHA severe-injury report for Plastiform Packaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
114 BEACH STREET, BLDG 6
City
ROCKAWAY
State
NJ
ZIP
07866
Mailing
114 BEACH STREET, BLDG 6, ROCKAWAY, NJ 07866
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
18
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3042.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) Production Area    The employer did not develop energy control procedures for use during tool/mold change for Thermoformer machines, thereby exposing employees to amputation hazards.  On 10/17/16, an employee changing mold on Thermoformer #3 (S/N 96077022)  suffered partial amputation of fingers on right hand when pressure box fell, crushing employees hand.    Condition occurred on or about 10/18/2016.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.147 C04 II C

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3042.00 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:    (a) Production Area    The written energy control procedures did not specifically outline the steps for removal of authorized employee's lockout/tagout device by the company or the transfer of lockout/tagout devices between shifts.       Condition observed on or about 10/18/2016.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.147 C06 I

Deleted Repeat Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7243.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  (a)Production Area  The employer did not conduct a periodic inspection of energy control procedures in 2016 to ensure compliance with the requirements of this standard.   Condition observed on or about 10/18/2016.  Plastiform Packaging Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(6)(i), which was contained in OSHA inspection number668239, citation number 1, item number 2 and was affirmed as a final order on 11/5/2012, with respect to a workplace located at 114 Beach St., Rockaway, NJ.
Recent events (2)
  • — I (R) $0
  • — Z (R) $7243

View PLASTIFORM PACKAGING, INC.'s full OSHA safety record →