Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DELTA DOOR COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DELTA DOOR COMPANY, INC. in 5210 ASHLEY CT., HOUSTON, TX 77041 (NAICS 321911). OSHA activity number 341898542.

Watch Delta Door Company, INC. — free Get an email when a new federal OSHA severe-injury report for Delta Door Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5210 ASHLEY CT.
City
HOUSTON
State
TX
ZIP
77041
Mailing
5210 ASHLEY CT., HOUSTON, TX 77041
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3563.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  During September through November of 2016, at the facility where employees were exposed to amputation and caught-in hazards when performing service and/or maintenance tasks on equipment such as, but not limited to, the Wadkin GD5 molder and the Powermatic planer without utilizing the documented procedures for controlling hazardous energy.     b)  During October and November of 2016, at the facility where employees were exposed to amputation and caught-in hazards when performing service and/or maintenance tasks on equipment such as, but not limited to, Saw Stop table saws and the Extrema up-cut saw without developing, documenting, and utilizing procedures for controlling hazardous energy.
Recent events (3)
  • — R (S) $0
  • — C (S) $3563
  • — Z (S) $3563

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   During September through November of 2016, at the facility where employees were exposed to amputation and caught-in hazards when performing service and/or maintenance tasks on equipment such as, but not limited to, the Wadkin GD5 molder, the Powermatic planer, Saw Stop table saws and the Extrema up-cut saw without applying a lockout or tagout device at the disconnects.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 II B

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3563.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    During September through November of 2016, at the facility where employees were exposed to amputation and caught-in hazards when performing service and/or maintenance tasks on equipment such as, but not limited to, the Wadkin GD5 molder without outlining the steps for isolating the pneumatic energy to the equipment.
Recent events (3)
  • — R (S) $0
  • — C (S) $3563
  • — Z (S) $3563

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341898542.