1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FLOWSERVE US INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FLOWSERVE US INC. in 299 GILLIAM ST., CORPUS CHRISTI, TX 78409 (NAICS 811310). OSHA activity number 341901734.

Watch Flowserve US INC. — free Get an email when a new federal OSHA severe-injury report for Flowserve US INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FLOWSERVE US INC.
Site address
299 GILLIAM ST.
City
CORPUS CHRISTI
State
TX
ZIP
78409
Mailing
5215 N. O'CONNER BLVD. SUITE 2300, IRVING, TX 75039
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
22
Ownership type
A

6 citations on file for this inspection.

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $10158.00 · Current $10158.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    On or about November 9, 2016, at the paint booth building, the employer did not provide a medical evaluation as required for an employee who wears a half-face respirator while painting machinery parts.
Recent events (2)
  • — I (O) $10158
  • — Z (S) $10158

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:     On or about November 9, 2016, at the paint booth building, the employer did not provide a fit-test as required for an employee who wears a half-face respirator while painting machinery parts.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $9959.00 · Current $8000.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On November 9,2016, and at times prior thereto, in the high bay, employees used a vertical turret lathe that was not guarded to machine equipment.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $9959

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $5079.00 · Current $2000.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about November 9, 2016, in the center of the main shop building, the employer did not ensure the tongue guard on a pedestal grinder was adjusted properly.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $5079

1910.303 G01

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about November 9, 2016, in the main shop between the portable office building and the north wall, employees engaged in machining activities did not adequate access to an electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $9961.00 · Current $3000.00 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    On or about November 9, 2016, at the paint booth building, an employee painted parts using paints that contain hazardous chemicals. The employer did not train this employee on hazardous chemicals.    Flowserve US Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 941167, citation number 1, item number 1 and was affirmed as a final order on 01/09/2013, with respect to a workplace located at 1400 Powis Court, West Chicago, IL 60185.
Recent events (2)
  • — I (O) $3000
  • — Z (R) $9961

View FLOWSERVE US INC.'s full OSHA safety record →