1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FLOWSERVE US INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FLOWSERVE US INC in 5757 GENOA-RED BLUFF ROAD, PASADENA, TX 77507 (NAICS 811310). OSHA activity number 343060992.

Watch Flowserve US INC — free Get an email when a new federal OSHA severe-injury report for Flowserve US INC is published. One employer, no account, unsubscribe in one click.
Establishment
FLOWSERVE US INC
Site address
5757 GENOA-RED BLUFF ROAD
City
PASADENA
State
TX
ZIP
77507
Mailing
5215 N O'CONNOR BLVD #2300, IRVING, TX 75039
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.132 D01

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5543.00 · Current $0.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  a) At the facility, pump repair areas: On or about April 3, 2018 the employer did not assess and determine the type off PPE needed for employees opening pumps containing residual hazardous chemicals.
Recent events (3)
  • — F (S) $0
  • — C (S) $5543
  • — Z (S) $5543

1910.134 D01 III

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $7391.00 · Current $0.00 Reduced
29 CFR 1910.134(d)(1)(iii): When the employer was unable to identify or reasonably estimate the employee exposure, the employer did not consider the atmosphere to be IDLH:  a) At the facility: Employees were exposed to inhalation hazards when opening pumps with residual hazardous chemicals without estimating the employee exposure.
Recent events (3)
  • — F (S) $0
  • — C (S) $7391
  • — Z (S) $7391

1910.134 D03 III B 2

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $7391.00 · Current $7391.00
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  a) At the facility: On or about April 3, 2018, the employer did not implement a change schedule for respirator cartridges not equipped with an end of service life indication to ensure the cartridges were changed before the end of their service life when employees were opening pumps.
Recent events (3)
  • — F (O) $7391
  • — C (S) $7391
  • — Z (S) $7391

1910.151 C

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $9239.00

Hazardous substances 1860

29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) At the facility, pump repair areas: On or about April 3, 2018 where employees were exposed to corrosive chemicals when servicing pumps without the eye wash station being readily accessible.
Recent events (3)
  • — F (S) $9239
  • — C (S) $9239
  • — Z (S) $9239

1910.333 C02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $0.00 Reduced
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.  a) At the facility, pump repair areas:  the employer did not ensure only qualified persons accessed the 480 volt electrical enclosures on serviced pumps for final settings by computer to control components, exposing employees to a shock and electrocution hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.335 A01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $9239.00
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  a) At the facility, pump repair areas:  the employer did not provide employees with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed when they accessed the 480 volt electrical enclosures on pumps to connect control system components, exposing employees to a shock and electrocution hazard.
Recent events (3)
  • — F (S) $9239
  • — C (S) $0
  • — Z (S) $0

1910.134 C03

Deleted Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1037.00 · Current $0.00 Reduced
29 CFR 1910.134(c)(3): The employer did not designate a program administrator who was qualified by appropriate training or experience to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness:  a) At the facility, pump repair areas: On or about April 3, 2018 the employer did not designate a program administrator who was qualified by appropriate training or experience to administer or oversee the respiratory protection program and to conduct the required evaluations of program effectiveness when employees were exposed to hazardous air contaminants during opening of pumps for refurbishment.
Recent events (3)
  • — F (O) $0
  • — C (O) $1037
  • — Z (O) $1037

View FLOWSERVE US INC's full OSHA safety record →