OSHA Inspection: L & M STEEL COMPANY INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of L & M STEEL COMPANY INC in 5523 DIETRICH RD, SAN ANTONIO, TX 78219 (NAICS 332312). OSHA activity number 341932838.

Watch L & M Steel Company INC — free Get an email when a new federal OSHA severe-injury report for L & M Steel Company INC is published. One employer, no account, unsubscribe in one click.
Site address
5523 DIETRICH RD
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
5523 DIETRICH RD, SAN ANTONIO, TX 78219
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
80
Ownership type
A

4 citations on file for this inspection.

1910.23 D01

Serious Gravity 1 1 instance 80 exposed
Issued
Abate by
Penalty
Initial $3802.00 · Current $2281.00 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:  Front office exit:  On or about November 16, 2016, employees were exposed to a fall hazard, while ascending and descending a stairway which was not equipped with standard stair railings or handrails.
Recent events (2)
  • — I (S) $2281.2
  • — Z (S) $3802

1910.219 C04 I

Serious Gravity 5 1 instance 80 exposed
Issued
Penalty
Initial $4310.00 · Current $2586.00 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  Production area:  On or about November 16, 2016, employees were exposed to a caught in hazard, while working next to an unguarded power transmission rotating shaft on a KRB shearing machine.
Recent events (2)
  • — I (S) $2586
  • — Z (S) $4310

1910.303 B02

Serious Gravity 1 1 instance 80 exposed
Issued
Penalty
Initial $3802.00 · Current $2281.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Break room:  On or about November 16, 2016, employees were exposed to an electrical hazard, while operating a microwave that was plugged directly into a power strip.
Recent events (2)
  • — I (S) $2281.2
  • — Z (S) $3802

1910.303 F02

Serious Gravity 1 1 instance 80 exposed
Issued
Abate by
Penalty
Initial $3802.00 · Current $2281.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Production area, 42 circuit breaker panel:  On or about November 16, 2016, employees were exposed to electrical hazards from a circuit breaker panel that did to have all the circuit breakers labeled for equipment being used.
Recent events (2)
  • — I (S) $2281.2
  • — Z (S) $3802

View L & M STEEL COMPANY INC's full OSHA safety record →