OSHA Inspection: WUHL SHAFMAN LIBERMAN CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WUHL SHAFMAN LIBERMAN CORP. in 2-44 CORNELIA ST, NEWARK, NJ 07105 (NAICS 424480). OSHA activity number 341981025.

Watch Wuhl Shafman Liberman Corp. — free Get an email when a new federal OSHA severe-injury report for Wuhl Shafman Liberman Corp. is published. One employer, no account, unsubscribe in one click.
Site address
2-44 CORNELIA ST
City
NEWARK
State
NJ
ZIP
07105
Mailing
2-44 CORNELIA ST, NEWARK, NJ 07105
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424480
Employees
350
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7243.00 · Current $5000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards from rollover while operating a forklift without a restraint system.    Location: 2-44 Cornelia, St., Newark, NJ (Produce Packaging Area)    a) A powered Industrial Equipment, Forklift Model #TMC Pro Cb 15, was not equipped with operator restraint devices or seat belts.  An employee was observed operating the forklift without the use of seat belt; on or about 12/8/16.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7243

1910.36 D01

Serious Gravity 5 2 instances 10 exposed
Issued
Penalty
Initial $10864.00 · Current $5000.00 Reduced
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside was not provided.    Location: 84 Lockwood St., Newark, NJ.    a) In the event of an emergency some employees may require special knowledge on how to operate the door in its current condition. There was no panic bar provided at the emergency discharge door; on or about 12/8/16.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $10864

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $5432.00 · Current $5000.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    Location: 2-44 Cornellia St., Newark, NJ (Produce Packaging Area)    a) Employer utilized various temporary extension cords as a permanent connection to power an industrial heavy duty light fixture.  The extension cords were not used as specified as employer used it to capacity daily thereby increasing overheating and thus creating a potential fire hazard at the facility; on or about 12/18/16.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5432

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341981025.