RAVENNA, OH —
OSHA Inspection: DURACOTE IC DISC CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DURACOTE IC DISC CORPORATION in 350 NORTH DIAMOND ST., RAVENNA, OH 44266 (NAICS 326130). OSHA activity number 342017217.
Where did this inspection happen?
- Establishment
- DURACOTE IC DISC CORPORATION
- Site address
- 350 NORTH DIAMOND ST.
- City
- RAVENNA
- State
- OH
- ZIP
- 44266
- Mailing
- 350 NORTH DIAMOND ST., RAVENNA, OH 44266
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326130
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C02 I
- Issued
- Penalty
- Initial $2173.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about January 10, 2017, employees permitted to wear a half mask air purifying respirator on an optional basis when wiping rollers on the UV line with methyl ethyl ketone had not been provided with Appendix D information.
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about January 10, 2017, employees permitted to wear half mask air purifying respirators while wiping rollers on the UV line had not been provided with a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 D01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: On or about January 10, 2017, the employer had not evaluated respiratory hazards on the UV line where employees wiping rollers were exposed to methyl ethyl ketone at a concentration of 1052 parts per million (ppm) when sampled for a 15 minute short term exposure limit (STEL).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D04 III
- Issued
- Penalty
- Initial $3622.00 · Current $2475.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations: On or about January 10, 2017, standard electrical outlets in the form of an extension cord and a power strip were utilized a flammable storage room in which category 1 and 2 flammable liquids including, but not limited to acetone, methyl ethyl ketone, isobutyl isobutyrate, and isopropyl alcohol were stored.
Recent events (2)
- — I (S) $2475
- — Z (S) $3622
1910.305 G01 IV A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about January 10, 2017, an extension cord was run through the doorway of the flammable storage room to power a scale and equipment in a mixing area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV C
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, floors, or similar openings: a. On or about January 10, 2017, an extension cord was run through the doorway of the flammable storage room to power a scale and equipment in a mixing area. b. On or about January 10, 2017, flexible cables powering equipment that heated compounds were run through a doorway on the UV line
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at DURACOTE IC DISC CORPORATION
RAVENNA, OH—2017-01-10 00:00:00
DURACOTE IC DISC CORPORATION
View DURACOTE IC DISC CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 326130)
DANVILLE, KY—2026-07-09
69313 - TRANSNAV TECHNOLOGIES INC
CINCINNATI, OH—2026-06-30
FORMICA CORPORATION
ERIE, PA—2026-06-24
HAYSITE REINFORCED PLASTICS, LLC
OAK CREEK, WI—2026-05-19
BAY VIEW INDUSTRIES, INC.
SOUTH EUCLID, OH—2026-05-06
ROECHLING CORP.
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342017217.