Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DURACOTE IC DISC CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DURACOTE IC DISC CORPORATION in 350 NORTH DIAMOND ST., RAVENNA, OH 44266 (NAICS 326130). OSHA activity number 342017217.

Watch Duracote IC Disc Corporation — free Get an email when a new federal OSHA severe-injury report for Duracote IC Disc Corporation is published. One employer, no account, unsubscribe in one click.
Site address
350 NORTH DIAMOND ST.
City
RAVENNA
State
OH
ZIP
44266
Mailing
350 NORTH DIAMOND ST., RAVENNA, OH 44266
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326130
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.134 C02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $2173.00 · Current $1000.00 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    On or about January 10, 2017, employees permitted to wear a half mask air purifying respirator on an optional basis when wiping rollers on the UV line with methyl ethyl ketone had not been provided with Appendix D information.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2173

1910.134 C02 II

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    On or about January 10, 2017, employees permitted to wear half mask air purifying respirators while wiping rollers on the UV line had not been provided with a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  On or about January 10, 2017, the employer had not evaluated respiratory hazards on the UV line where employees wiping rollers were exposed to methyl ethyl ketone at a concentration of 1052 parts per million (ppm) when sampled for a 15 minute short term exposure limit (STEL).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $3622.00 · Current $2475.00 Reduced
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations:    On or about January 10, 2017, standard electrical outlets in the form of an extension cord and a power strip were utilized a flammable storage room in which category 1 and 2 flammable liquids including, but not limited to acetone, methyl ethyl ketone, isobutyl isobutyrate, and isopropyl alcohol were stored.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3622

1910.305 G01 IV A

Serious Gravity 5 2 instances 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about January 10, 2017, an extension cord was run through the doorway of the flammable storage room to power a scale and equipment in a mixing area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV C

Serious Gravity 5 2 instances 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, floors, or similar openings:   a. On or about January 10, 2017, an extension cord was run through the doorway of the flammable storage room to power a scale and equipment in a mixing area.     b. On or about January 10, 2017, flexible cables powering equipment that heated compounds were run through a doorway on the UV line
Recent events (2)
  • — I (S) $0
  • — Z (S) $0