CINCINNATI, OH —
OSHA Inspection: ROBLES ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROBLES ROOFING, LLC in 4674 GREENWALD CT., CINCINNATI, OH 45248 (NAICS 238160). OSHA activity number 342034253.
Where did this inspection happen?
- Establishment
- ROBLES ROOFING, LLC
- Site address
- 4674 GREENWALD CT.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45248
- Mailing
- 7259 GERMAN TOWN PIKE, GERMANTOWN, OH 45327
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $3803.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Located on the north side of an exterior residential low pitch roof structure, employees were observed installing Ice and Water Armor Underlayment while not utilizing any fall protection system. Potential fall height was measured to be 18.6 feet with a roof pitch of 4/12.
Recent events (2)
- — I (S) $1000
- — Z (S) $3803
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. Located on the north side of an exterior residential low pitch roof structure, employees were observed installing Ice and Water Armor Underlayment without utilizing a fall protection system and had not been trained by the employer to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. Employees were exposed to a potential fall height of greater than 18 feet above the ground below with a roof pitch measured to be 4/12. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3803
More inspections at ROBLES ROOFING, LLC
THE COLONY, TX—2024-08-29 00:00:00
ROBLES ROOFING LLC
THE COLONY, TX—2024-08-29 00:00:00
ROBLES ROOFING LLC
LANCASTER, OH—2023-06-15 00:00:00
ROBLES ROOFING LLC
CINCINNATI, OH—2019-11-13 00:00:00
ROBLES ROOFING, LLC
OKLAHOMA CITY, OK—2010-03-09 00:00:00
ROBLES ROOFING LLC
View ROBLES ROOFING, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342034253.