Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MICON MANN INDUSTRIAL CONTRACTOR

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MICON MANN INDUSTRIAL CONTRACTOR in 500 W MAIN ST, EMMETT, ID 83617 (NAICS 423330). OSHA activity number 342049004.

Watch Micon Mann Industrial Contractor — free Get an email when a new federal OSHA severe-injury report for Micon Mann Industrial Contractor is published. One employer, no account, unsubscribe in one click.
Site address
500 W MAIN ST
City
EMMETT
State
ID
ZIP
83617
Mailing
11523 NORTH REED ROAD, HAYDEN, ID 83835
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.760 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $5070.00
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  (a) Second floor, east side of the re-saw building: Employees walking to work locations and/or installing structural steel components proximal to a partially decked area  were  not protected from falls of 15' 4" onto concrete.   (b) Second floor, south side of the re-saw building: Employees walking in the area  and/or  prepping structural steel components near the opening in the wall used to pass materials were not protected from falls of 15' 4" onto concrete and construction materials   Note: Abatement certification and documentation ARE required for this item.
Recent events (1)
  • — Z (S) $5070

1926.760 D01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $5070.00
29 CFR 1926.760(d)(1): Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components did not conform to the criteria in 1926.502  (a)  Roof of re-saw building: On or before January 20, 2017 up to seven workers removing snow from the roof were connected to a horizontal life line  which had not been designed, installed, and used, under the supervision of a qualified person.  (b)  Roof of re-saw building:  On or before January 20, 2017 the Miller "Mighty Lite" self-retracting lifeline was not taken out of service after the impact indicator had been activated.    Note: Abatement certification and documentation are required for this item
Recent events (1)
  • — Z (S) $5070

1926.502 I04

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1847.00 · Current $1847.00
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  (a) Second floor of the re-saw building: On and before January 20, 2017 plywood covering holes in the floor were not marked to indicate the presence of a hazard.  Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (S) $1847