Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: YONI GARCIA-VASQUEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of YONI GARCIA-VASQUEZ in 8850 FERGUSON RD., DALLAS, TX 75228 (NAICS 238130). OSHA activity number 342079878.

Watch Yoni Garcia-Vasquez — free Get an email when a new federal OSHA severe-injury report for Yoni Garcia-Vasquez is published. One employer, no account, unsubscribe in one click.
Establishment
YONI GARCIA-VASQUEZ
Site address
8850 FERGUSON RD.
City
DALLAS
State
TX
ZIP
75228
Mailing
1313 LEXINGTON DR., GARLAND, TX 75041
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

10 citations on file for this inspection.

1926.20 B03

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1350.00 Reduced
29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation.    (a) Building #10, employees were utilizing a Magnesium skill saw and other equipment that was connected to a frayed and worn extension cord that was not tagged, identified or otherwise taken out of service.    (b) Building #10, employees were utilizing an air compressor and other equipment that was connected to a frayed and worn extension cord that was not tagged, identified or otherwise taken out of service.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $3803

1926.416 E01

Serious Gravity 10 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) Building #10, employees were utilizing a Magnesium skill saw and other equipment requiring electrical power were exposed to electrocution, and other electrical hazards from an electrical cord being frayed and worn.   (b) Building #10, employees were utilizing an air compressor and other equipment requiring electrical power were exposed to electrocution, and other electrical hazards from an electrical cord being frayed and worn.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 10 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1350.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    (a) Building #10, pump jack scaffold #1, the employer did not ensure the scaffold was erected, moved, dismantled, or altered with supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration. The lack of direction by a competent person exposed the employees to fall hazards of approximately 36-feet.     (b) Building #10, pump jack scaffold #2, the employer did not ensure the scaffold was erected, moved, dismantled, or altered with supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration. The lack of direction by a competent person exposed the employees to fall hazards of approximately 36-feet.     (c)Building #10, pump jack scaffold #3, the employer did not ensure the scaffold was erected, moved, dismantled, or altered with supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration. The lack of direction by a competent person exposed the employees to fall hazards of approximately 36-feet.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $3803

1926.451 C02

Serious Gravity 10 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  (a) Building #10, pump jack scaffold #1, poles and posts did not bear base plates and mud sills.   (b) Building #10, pump jack scaffold #2, poles and posts did not bear base plates and mud sills.   (c) Building #10, pump jack scaffold #3, poles and posts did not bear base plates and mud sills.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:  (a) Building #10, pump jack scaffold #2, footings were not on a level surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J05

Serious Gravity 10 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(5): When poles were made of wood, the pole lumber was not straight-grained, free of shakes, large loose or dead knots, and other defects which might impair strength:   (a) Building #10, pump jack scaffold #1, scaffold poles had dead knots within the wood.  (b) Building #10, pump jack scaffold #2,scaffold poles had dead knots within the wood.  (c) Building #10, pump jack scaffold #3, scaffold poles had dead knots within the wood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J07

Serious Gravity 10 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(7): When two by fours were spliced to make a pole, mending plates were not installed at all splices to develop the full strength of the member:   (a) Building #10, pump jack scaffold #1, poles did not have mending plates installed at the splices.  (b) Building #10, pump jack scaffold #2, poles did not have mending plates installed at the splices.   (c) Building #10, pump jack scaffold #3, poles did not have mending plates installed at the splices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1350.00 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    (a) Building #10, pump jack scaffold #2, the employer did not ensure that guardrails or other suitable fall protection was installed or utilized throughout the working platform of the scaffold.     (b) Building #10, pump jack scaffold #3, the employer did not ensure that guardrails or other suitable fall protection was installed or utilized throughout the working platform of the scaffold.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $3803

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1350.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.     (a) Building #10 near pump jack scaffold #3 , employees were utilizing and setting up an extension ladder,  and were exposed to a fall hazard.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $720.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     (a) Building #10, pump jack scaffold #2, an extension ladder was used to access the upper landing surface and did not extend at least 3-feet.
Recent events (2)
  • — I (S) $720
  • — Z (S) $2173

RNWBL