ARLINGTON HEIGHTS, IL —
OSHA Inspection: ROBERT CARR DBA ROBERT CARR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROBERT CARR DBA ROBERT CARR in 1236 N. CHICAGO AVE., ARLINGTON HEIGHTS, IL 60004 (NAICS 238130). OSHA activity number 342134343.
Where did this inspection happen?
- Establishment
- ROBERT CARR DBA ROBERT CARR
- Site address
- 1236 N. CHICAGO AVE.
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60004
- Mailing
- 4417 E. LAKESHORE DR., WONDER LAKE, IL 60097
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
11 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $305.00 · Current $305.00
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Robert Carr dba Robert Carr, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 04/28/2017 01 02a 04/28/2017 01 02b 04/28/2017 01 03 04/28/2017 01 04a 04/28/2017 01 04b 04/28/2017 01 05 04/28/2017 01 06 05/25/2017 01 07a 04/28/2017 01 07b 04/28/2017 01 05 04/28/2017 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $305
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports. a) On February 27, 2017, employees were exposed to the hazard of falling approximately 15 feet, while performing carpentry work from a wooden pole scaffold platform that was not fully planked.
Recent events (1)
- — Z (S) $2716
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $2173.00
General-duty citation text
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access: a) On February 27, 2017, employees accessed a wooden pole scaffold platform up to approximately 6 feet above the deck by climbing up an A frame ladder and stepping from the top rung of the ladder to the scaffold platform.
Recent events (1)
- — Z (S) $2173
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) On February 27, 2017, employees performing carpentry work were standing on the top step of an 6 foot A-frame stepladder in order to access a wooden pole scaffold platform.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) On February 27, 2017, employees were exposed to the hazard of falling while performing carpentry work from a wooden pole scaffold platform elevated approximately 15 feet above the second floor deck.
Recent events (1)
- — Z (S) $3803
1926.452 A03
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1926.452(a)(3): Diagonal bracing in both directions was not installed across the entire inside face of double-pole scaffolds used to support loads equivalent to a uniformly distributed load of 50 pounds or more per square foot: a) On February 27, 2017, employees were performing carpentry work from a wooden pole scaffold that did not have diagonal bracing in both directions installed.
Recent events (1)
- — Z (S) $2716
1926.452 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(a)(4): Diagonal bracing in both directions was not installed across the entire outside face of all double- and single-pole scaffolds: a) On February 27, 2017, employees were performing carpentry work from a wooden pole scaffold that did not have diagonal bracing installed in both directions across the entire outside face of the scaffold.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On February 27, 2017, employees were exposed to fall hazards of up to approximately 21.9 feet while performing carpentry work to a new construction single family home. b) On February 27, 2017, employees were exposed to fall hazards of from an uncovered floor hole leading to the basement by the stairway.
Recent events (1)
- — Z (S) $3803
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards, to enable each employee to recognize fall hazards and the procedures to be followed in order to minimize these hazards: a) On or around February 27, 2017 employees were exposed to fall hazards while performing carpentry work. The employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize these hazards.
Recent events (1)
- — Z (S) $2716
1926.1052 C01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $2173.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge: a) On February 27, 2017, employees were using a stairway from the first floor to the second floor that was equipped with a stairrail system on only one side of the stairway leaving one side unprotected.
Recent events (1)
- — Z (S) $2173
1926.1052 C12
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems which met the criteria contained in Subpart M of 29 CFR 1926: a) On February 27, 2017, employees used the stairway to access the second floor where the landing did not have a guardrail system.
Recent events (1)
- — Z (S) $0
More inspections at ROBERT CARR DBA ROBERT CARR
VOLO, IL—2025-03-05
ROBERT CARR DBA ROBERT CARR
View ROBERT CARR DBA ROBERT CARR's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342134343.