HOUSTON, TX —
OSHA Inspection: TREADWRIGHT TIRES, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TREADWRIGHT TIRES, LLC in 6501 NAVIGATION BLVD. #100, HOUSTON, TX 77011 (NAICS 326212). OSHA activity number 342158102.
Where did this inspection happen?
- Establishment
- TREADWRIGHT TIRES, LLC
- Site address
- 6501 NAVIGATION BLVD. #100
- City
- HOUSTON
- State
- TX
- ZIP
- 77011
- Mailing
- 6501 NAVIGATION BLVD. #100, HOUSTON, TX 77011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326212
- Employees
- 32
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition: a) At the facility, where the the walking working surfaces were not clean and clear of rubber tire debris.
Recent events (1)
- — Z (O) $0
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from the floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) At the facility, where the rotating shaft on the Atec Non Destructive Testing (NDT) Machine, model number 15NDTC, serial numbers 2161012 was not guarded.
Recent events (1)
- — Z (O) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) At the facility, where the Westinghouse electrical panel door for the building lighting was not used in accordance with the listing and labeling. The panel door was missing the latch to keep it closed which exposed employees to electrical hazards. b) At the facility, where the relocatable power tap was not used in accordance with the listing and labeling. The relocatable power tap was affixed to the pegboard near the Atec Non Destructive Testing (NDT) Machine, model number 15NDTC, serial numbers 2161012.
Recent events (1)
- — Z (O) $0
1910.303 C03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(c)(3)(i): Splices and joints and free ends were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: a) At the facility, where the flexible cord conductors where not covered with insulation.
Recent events (1)
- — Z (O) $0
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) At the facility on March 8, 2017, where the orange flexible cord that supplied electrical power to the portable industrial fan was not inspected for defects prior to use. The flexible cord insulation was spliced and the conductors were held together with a piece of tape.
Recent events (1)
- — Z (O) $0
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a) At the facility, where the tire spider repair inspection machine #1 was turned and off with a pair of hand pliers.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 326212)
AKRON, OH—2026-06-12
ACE RUBBER PRODUCTS DIVISION GARRO TREAD CORPORATION
SOUTH WINDSOR, CT—2026-01-29
PETE'S TIRE BARN INC.
SOUTH WINDSOR, CT—2025-12-30
PETE'S TIRE BARNS INC.
DUNDEE, MS—2025-11-12
FREEBYRD, INC
BRAINERD, MN—2025-10-01
109970 - HEARTLAND RETREADING OF BRAINERD INC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342158102.