BERNHARDS BAY, NY —
OSHA Inspection: MCINTOSH BOX & PALLET CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCINTOSH BOX & PALLET CO., INC. in 741 STATE ROUTE 49, BERNHARDS BAY, NY 13028 (NAICS 321920). OSHA activity number 342240033.
Where did this inspection happen?
- Establishment
- MCINTOSH BOX & PALLET CO., INC.
- Site address
- 741 STATE ROUTE 49
- City
- BERNHARDS BAY
- State
- NY
- ZIP
- 13028
- Mailing
- 5846 HERITAGE LANDING DRIVE, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 43
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.101 B
- Issued
- Penalty
- Initial $5541.00 · Current $3602.00 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Maintenance Department, on or about 4/11/2017: (5) Five compressed gas cylinders stored next to the overhead door were not secured to prevent them from falling over.
Recent events (2)
- — I (S) $3601.65
- — Z (S) $5541
1910.253 B04 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1/2 hour. a) Maintenance, on or about 4/11/17: Oxygen and acetylene compressed gas cylinders in storage were not separated by a distance of 20 ft. or by a non-combustible partition having a fire resistance rating of at least one hour.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Penalty
- Initial $5541.00 · Current $3602.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Cell#1, New Building, on or about 4/11/17: Metal industrial fan did not have a permanent, continuous and effective path ground in that the ground pin was missing from the plug connector.
Recent events (2)
- — I (S) $3601.65
- — Z (S) $5541
More inspections at MCINTOSH BOX & PALLET CO., INC.
BERNHARDS BAY, NY—2025-07-24 00:00:00
MCINTOSH BOX & PALLET CO., INC.
GENEVA, NY—2024-04-11 00:00:00
MCINTOSH BOX & PALLET CO INC.
BERNHARDS BAY, NY—2024-03-21 00:00:00
MCINTOSH BOX & PALLET CO., INC.
CENTRAL SQUARE, NY—2023-04-12 00:00:00
MCINTOSH BOX & PALLET CO., INC.
CENTRAL SQUARE, NY—2022-04-04 00:00:00
MCINTOSH BOX & PALLET CO., INC.
View MCINTOSH BOX & PALLET CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
LAKELAND, FL—2026-07-16 00:00:00
ELIJAH WHOLESALE, LLC.
SOUTH HOLLAND, IL—2026-07-16 00:00:00
CANTARERO PALLETS, INC.
DECATUR, GA—2026-07-15 00:00:00
PALLETS ACQUISITION LLC
CLANTON, AL—2026-07-14 00:00:00
SPECWOOD PRODUCTS, INC.
FITCHBURG, MA—2026-07-10 00:00:00
KELLEY WOOD PRODUCTS, INC.
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342240033.