Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HOUSE OF CHEATHAM, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HOUSE OF CHEATHAM, INC. in 1550 ROADHAVEN DRIVE, STONE MOUNTAIN, GA 30083 (NAICS 325620). OSHA activity number 342263142.

Watch House OF Cheatham, INC. — free Get an email when a new federal OSHA severe-injury report for House OF Cheatham, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1550 ROADHAVEN DRIVE
City
STONE MOUNTAIN
State
GA
ZIP
30083
Mailing
1550 ROADHAVEN DRIVE, STONE MOUNTAIN, GA 30083
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325620
Employees
50
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $5387.00 · Current $4000.00 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:     a.  1550 Roadhaven Drive, Stone Mountain, GA (Over the Maintenance Shop) - Maintenance Employees were exposed to fall hazard.  The employees are required to access the upper level mezzanine storage area to retrieved items pertaining to the shop area such as, but not limited to boxes and other excess shop materials.  The mezzanine area was not equipped with the standard guardrails along the open-sides of the storage area, exposing employees to a fall of 11' to lower level, on or about 04/19/17.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5387

1910.147 C04 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5387.00 · Current $4000.00 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     1550 Roadhaven Drive, Stone Mountain, GA - On or about 04/19/17,  Employees were exposed to sudden energization or start-up of multi-energy source equipment/machinery such as, but not limited to line 1 - 11 machineries.  The company's written lockout/tagout specific procedures were found with the following deficiencies:          a.  The energy control procedures did not specifically outline the steps for placement of              locks onto the multi-energy source disconnect apparatus.          b. The energy control procedures did not specifically outline the steps for the removal of             locks and restoring the equipment back to service.           c.  Specific requirements for testing the machine or equipment to determine and verify              the effectiveness of lockout devices, tagout devices and other energy control             measures were not included in the specific procedures.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5387

1910.147 C06 I

Serious Gravity 1 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a. 1550 Roadhaven Drive, Stone Mountain, GA - Employees were exposed to hazard of sudden energization of moving parts of equipment.  Employees (maintenance) perform servicing and maintenance on various machinery and equipment which has multi-energy source, such as electrical, pneumatic and hydraulic. An internal audit was not performed to ensure de-energization procedures were being properly implemented, on or about 04/19/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4310.00 · Current $0.00 Reduced
29 CFR 1910.212(a) (1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a.  1550 Roadhaven Drive, Stone Mountain, GA (Line #2 Bundler) - Employees were exposed to caught-between and/or struck-by hazard. The employees are maneuvering the interlock switch to continue to run when the front glass door is open, exposing employees to struck-by hazard as the machine continue to operate.  The employees are by-passing the interlock switch (guard) to run the line in a jog mode, on or about 04/19/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4310

View HOUSE OF CHEATHAM, INC.'s full OSHA safety record →