Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of FOGARTY HOME IMPROVEMENT, LLC in 417 S. DEARBORN ST., CHICAGO, IL 60605 (NAICS 238130). OSHA activity number 342263951.

Watch Fogarty Home Improvement, LLC — free Get an email when a new federal OSHA severe-injury report for Fogarty Home Improvement, LLC is published. One employer, no account, unsubscribe in one click.
Site address
417 S. DEARBORN ST.
City
CHICAGO
State
IL
ZIP
60605
Mailing
PO BOX 31376, CHICAGO, IL 60631
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.502 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4183.00 · Current $3000.00 Reduced
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:    a.  On or about April 20, 2017, at the above addressed jobsite, on the 11th floor, an employee performing construction operations was exposed to falls of approximately one hundred ten (110) feet created by the top rails on the guard rails being at the wrong height and incomplete to protect employees from fall hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4183

1926.502 B02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(b)(2)(i): Midrails, when used, were not installed at a height midway between the top edge of the guardrail system and the walking/working level; screens and mesh, when used, did not extend from the top rail to the walking/working level and along the entire opening between top rail supports; Intermediate members, when used between posts, were more than 19 inches (.5 m) apart; Other structural members were installed such that there are no openings in the guardrail system that are more than 19 inches (48 cm) wide.  a.  On or about April 20, 2017, at the above addressed jobsite, on the 11th floor, an employee performing construction operations was exposed to falls of approximately one hundred ten (110) feet created by the mid rails on the guard rails being at the wrong height and incomplete to protect employees from fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.851 C

Deleted Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $4183.00 · Current $0.00 Reduced
29 CFR 1926.851(c): In a multistory building, stairwell(s) being used were not properly illuminated by either natural or artificial means:  a. On or about April 20, 2017, at the above addressed jobsite, employees performing construction operations were exposed to falls of approximately nine (9) feet or one (1) story due to improper lighting in stairwells and stair landings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4183

1926.1052 C01 II

Serious Gravity 10 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $4183.00 · Current $2000.00 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a.  On or about April 20, 2017, at the above addressed jobsite, the stairway to the second floor and from floors ten through twelve was not provided with handrails, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4183

1926.1052 C12

Serious Gravity 10 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926:   a.  On or about April, 20 2017, at the above addressed jobsite, the stairway landing to the 10th floor from the 11th floor, was not provided with guardrail systems, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Deleted Repeat Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8366.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. On or about April 20, 2017, at the above addressed jobsite, an employee performing construction operations was exposed to falls of approximately one hundred twenty (110) feet, or 11 stories, created by the presence of incomplete guardrail systems.  Fogarty Home Improvement, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1926.501(b)(1), which was contained in OSHA inspection number 1149039, citation number 2, item number 1 and was affirmed as a final order on August 16, 2016, with respect to a workplace located at 1101 W. Randolph Street, Chicago IL.
Recent events (2)
  • — I (R) $0
  • — Z (R) $8366

View FOGARTY HOME IMPROVEMENT, LLC's full OSHA safety record →