GALESBURG, IL —
OSHA Inspection: NEW AGE SIDING & WINDOWS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEW AGE SIDING & WINDOWS, INC. in 404 ISLE ROYALE, GALESBURG, IL 61401 (NAICS 238160). OSHA activity number 342313087.
Where did this inspection happen?
- Establishment
- NEW AGE SIDING & WINDOWS, INC.
- Site address
- 404 ISLE ROYALE
- City
- GALESBURG
- State
- IL
- ZIP
- 61401
- Mailing
- 1290 W MAIN STREET, GALESBURG, IL 61401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: On or about May 9, 2017 employees performing roofing activities were exposed to fall hazards of approximately 9 feet and the employer did not have an effective safety and health program with specific work rules, competent person oversight, and employee training to govern employees' activities.
Recent events (3)
- — F (S) $1300
- — C (S) $2173
- — Z (S) $2173
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): On or about May 9, 2017 employees performing roofing activities were exposed to fall hazards of approximately 9 feet and the employer did not conduct frequent and regular inspections of the jobsite, materials, and equipment.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 F15 II
- Issued
- Abate by
- Penalty
- Initial $3259.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(15)(ii): The platform units were not secured to a scaffold to prevent their movement: On or about May 9, 2017 employees were working from a pick placed between two A-frame stepladders and the employer did not ensure that the platform was secured to a scaffold base.
Recent events (3)
- — F (S) $0
- — C (S) $3259
- — Z (S) $3259
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about May 9, 2017 employees were working from a pick placed between two A-frame stepladders and the employer did not ensure that the stepladders were used for the purposes for which they were designed: a. The rear section of the stepladder was not designed for standing and only extra heavy duty Type 1A or special duty type 1AA single and extension ladders were recommended for use with ladder jacks or planks (picks). b. The pick placed between the stepladders obstructed the path of the employees when they ascended and descended the ladder(s).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3259.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about May 9, 2017 employees performing roofing activities were exposed to fall hazards of approximately 9 feet and the employer did not ensure that employees used fall protection.
Recent events (3)
- — F (S) $0
- — C (S) $3259
- — Z (S) $3259
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about May 9, 2017 employees performing roofing activities were exposed to fall hazards of approximately 9 feet and the employer did not ensure employees were trained on the fall protection system to be used.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3259.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about May 9, 2017 employees performing roofing activities used stepladders to access the roof and were exposed to fall hazards of approximately 9 feet, and the employer did not ensure that the ladder used to access the roof extended at least 3 feet above the roof's eave.
Recent events (3)
- — F (S) $1500
- — C (S) $3259
- — Z (S) $3259
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about May 9, 2017 employees performing roofing activities used stepladders to access the roof and were exposed to fall hazards of approximately 9 feet, and the employer did not ensure employees were trained to recognize and avoid unsafe ladder usage.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342313087.