CLINTON, NY —
OSHA Inspection: NORTH COUNTRY STORAGE BARNS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORTH COUNTRY STORAGE BARNS in 4550 STATE ROUTE 233, CLINTON, NY 13323 (NAICS 238130). OSHA activity number 342328028.
Where did this inspection happen?
- Establishment
- NORTH COUNTRY STORAGE BARNS
- Site address
- 4550 STATE ROUTE 233
- City
- CLINTON
- State
- NY
- ZIP
- 13323
- Mailing
- 32660 US ROUTE 11, PHILADELPHIA, NY 13673
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 25
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2475.00 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) Southwest corner of building, first floor, on or about 5-11-17: Employees were operating a table saw for ripping purposes that was not equipped with non kick-back fingers or "dogs". b) Southwest corner of building, first floor, on or about 5-11-17: Employees were operating a table saw for ripping purposes that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $2475
- — Z (S) $3622
1926.304 I01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Southwest corner of building, first floor, on or about 5-11-17: Employees were operating a table saw for ripping purposes that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B02
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $3275.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) West side of building, on or about 5-11-17: Employees were working while standing on the top plate of a framed exterior partition that was less than 18 inches wide (5-1/2"), exposing the employees to a fall hazard of 10 feet 5 inches and/or 11 feet 1 inch. b) Entire building, on or about 5-11-17: Employees were working while standing on the bottom chord of wood roof trusses that were less than 18 inches wide (1-1/2"), exposing the employees to a fall hazard of 10 feet 5 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $3275
- — Z (S) $5070
1926.501 B15
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: a) West side of building, on or about 5-11-17: Employees were working while standing on the top plate of a framed exterior partition without fall protection, exposing the employees to a fall hazard of 10 feet 5 inches and/or 11 feet 1 inch. b) Entire building, on or about 5-11-17: Employees were working while standing on the bottom chord of wood roof trusses without fall protection, exposing the employees to a fall hazard of 10 feet 5 inches. c) North side of attic trusses, on or about 5-11-17: Employees were installing floor sheathing without fall protection, exposing the employees to a fall hazard of 10 feet 5 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Penalty
- Initial $2897.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) North side of building, on or about 5-11-17: Employees were accessing and exiting a work area by jumping up from or down to a step ladder, with a change in elevation of 37 inches, exposing the employees to a fall hazard of up to 10 feet 5 inches. b) South side of building, on or about 5-11-17: Employees were accessing and exiting a work area by jumping up from or down to a step ladder, with a change in elevation of 36 inches, exposing the employees to a fall hazard of up to 10 feet 5 inches.
Recent events (2)
- — I (S) $1875
- — Z (S) $2897
1926.1053 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) North side of building, on or about 5-11-17: Employees were accessing and exiting a work area while using the top step of a step ladder, exposing the employees to a fall hazard of 8 feet. b) South side of building, on or about 5-11-17: Employees were accessing and exiting a work area while using the top step of a step ladder, exposing the employees to a fall hazard of 8 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1051 A
- Issued
- Penalty
- Initial $2897.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) North side of building, on or about 5-11-17: Employees were accessing and exiting a work area by jumping up from or down to a step ladder, with a change in elevation of 37 inches, exposing the employees to a fall hazard of up to 10 feet 5 inches. b) South side of building, on or about 5-11-17: Employees were accessing and exiting a work area by jumping up from or down to a step ladder, with a change in elevation of 36 inches, exposing the employees to a fall hazard of up to 10 feet 5 inches.
Recent events (2)
- — I (S) $1875
- — Z (S) $2897
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge: a) Southeast corner of building, on or about 5-11-17: Employees were using a stairway without a hand rail, exposing the employees to a fall hazard of 84 inches. b) Southeast corner of building, on or about 5-11-17: Employees were using a stairway without a hand rail, exposing the employees to a fall hazard of 42 inches. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
MOUNT JULIET, TN—2026-07-17 00:00:00
M AND F CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
FAIRHOPE, AL—2026-07-16 00:00:00
FRANCISCO ARIAS
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342328028.