OSHA Inspection: MASE PROPERTY MANAGEMENT AND DEVELOPMENT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MASE PROPERTY MANAGEMENT AND DEVELOPMENT, LLC in 104 SLATER DRIVE, WERNERSVILLE, PA 19565 (NAICS 238160). OSHA activity number 342368487.

Watch Mase Property Management AND Development, LLC — free Get an email when a new federal OSHA severe-injury report for Mase Property Management AND Development, LLC is published. One employer, no account, unsubscribe in one click.
Site address
104 SLATER DRIVE
City
WERNERSVILLE
State
PA
ZIP
19565
Mailing
245 CRUM CREEK ROAD, MEDIA, PA 19063
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $305.00 · Current $305.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  Location: 104 Slater Drive Wernersville, PA  On or about August 30, 2017, the employer did not provide certification of corrective action for citation 1 item 1, citation 1 item 2, citation 2 item 1 and citation 2 item 2 for citations issued on August 4, 2017.
Recent events (1)
  • — Z (O) $305

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  104 Slater Drive, Wernersville PA - Employees were observed without head protection while working under roofing operations and were exposed to potential head injury from falling objects, on or about June 1, 2017.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1630

1926.150 C01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.150(c)(1)(i): At this job site, fire extinguishers were not provided for each 3,000 square ft. of the protected building area, or major fraction thereof:  a)  104 Slater Drive, Wernersville PA - Employees using multiple portable electric tools, a gasoline powered air compressor, and a gasoline powered ladder hoist did not have a portable fire extinguisher available on site in the event of a fire, on or about June 1, 2017.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1630

1926.501 B11

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems or personal fall arrest systems:  a) Main Roof -  A roofer was observed working on a steep roof approximately 18 feet above ground and was not protected from falling, on or about June 1, 2017.  b) Garage Roof - A roofer was observed working on a steep roof approximately 9 feet above ground and was not protected from falling, on or about June 1, 2017.  No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $3803

1926.403 B01 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose:  a) 104 Slater Drive, Wernersville PA - On or about June 1, 2017, a Magic Chef 120 volt microwave being used at this jobsite was listed and labeled for household use only.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0

1926.404 B01 II

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:  a) 104 Slater Drive, Wernersville PA - On or about June 1, 2017, employee(s) were using an extension cord to power a microwave oven that was not protected with a ground fault circuit interrupter (GFCI) protection.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342368487.