OSHA Inspection: CHASE CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHASE CORPORATION in 1527 LYONS, EVANSTON, IL 60201 (NAICS 325520). OSHA activity number 342416930.

Watch Chase Corporation — free Get an email when a new federal OSHA severe-injury report for Chase Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CHASE CORPORATION
Site address
1527 LYONS
City
EVANSTON
State
IL
ZIP
60201
Mailing
1527 LYONS, EVANSTON, IL 60201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
Employees
28
Ownership type
A

5 citations on file for this inspection.

1910.29 B10

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2789.00 Reduced
29 CFR 1910.29(b)(10):  The employer did not ensure that guardrail systems used at hoist area, equipped with  a removable guardrail section, consisted of a top rail and midrail, and were placed across the access opening between guardrail sections when employees were not performing hoisting operations. The employer may use chains or gates instead of a removable guardrail section at hoist areas if the employer demonstrates the chains or gates provide a level of safety equivalent to guardrails.    (a) Production - On June 22, 2017, the employer did not ensure that an adequate guardrail system consisting of a top and midrail was placed across the access opening on the mixer for the cold tape line.    (b) Production - On June 22, 2017, the employer did not ensure that an adequate guardrail system consisting of a top and midrail was installed across the access opening on the mixer for slitter #2.    In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2788.5
  • — Z (S) $5070

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $5070.00 · Current $2963.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:      (a) Faclity Wide -  On June 22, 2017, the employer failed to ensure that periodic inspections of the energy control procedures were performed annually and contained the required documentation such as the identification of the machine or equipment, inspection date, employees included and the person performing the inspection.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2962.85
  • — Z (S) $5070

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $5387.00 · Current $2878.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation and rotating parts:    (a) Shop - On June 22, 2017,  the employer did not ensure that the unused portion of the Johnson horizontal band saw was guarded to protect the operator from the hazard created by the un-used portion of the blade while in operation.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2878.15
  • — Z (S) $5387

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4310.00 · Current $2371.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):      (a) Production - On June 22, 2017, the employer failed to ensure that adequate methods of guarding were used to protect employees from rotating belts and pulleys on the Enviro slitter.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2370.5
  • — Z (S) $4310

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   (a) Production - On June 22, 2017, the employer failed to ensure that a junction box located by the power safety mat for the used to power up the safety mats was equipped with adequate covers on the Enviro slitter.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CHASE CORPORATION's full OSHA safety record →