WAUPACA, WI —
OSHA Inspection: SPIRIT METAL FAB LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SPIRIT METAL FAB LLC in 1850 GODFREY DRIVE, WAUPACA, WI 54981 (NAICS 333111). OSHA activity number 342571445.
Where did this inspection happen?
- Establishment
- SPIRIT METAL FAB LLC
- Site address
- 1850 GODFREY DRIVE
- City
- WAUPACA
- State
- WI
- ZIP
- 54981
- Mailing
- 1850 GODFREY DRIVE, WAUPACA, WI 54981
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $6374.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator: On or about August 23, 2017, the employer did not provided a Painter employee with a medical evaluation to determine the employee's ability to wear a full-face tight-fitting respirator with organic/particulate filter cartridges prior to the employee's required use of the respirator while powder coat painting in a spray booth. The Spirit Metal Fab LLC (previously Spirit Implement LLC) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1079291, citation number 1, item number 1c and was affirmed as a final order on December 10, 2015, with respect to a workplace located at 1850 Godfrey Drive, Waupaca, WI 54981.
Recent events (2)
- — I (R) $4500
- — Z (R) $6374
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $6374.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: On or about August 23, 2017, the employer did not ensure a Painter employee using a full-face tight-fitting respirator with organic/particulate filter cartridges passed an appropriate QLFT or QNFT prior to using the respirator while powder coat painting in a spray booth. The Spirit Metal Fab LLC (previously Spirit Implement LLC) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(f)(1), which was contained in OSHA inspection number 1079291, citation number 1, item number 1d and was affirmed as a final order on December 10, 2015, with respect to a workplace located at 1850 Godfrey Drive, Waupaca, WI 54981.
Recent events (2)
- — I (R) $0
- — Z (R) $6374
1910.134 H02 I
- Issued
- Abate by
- Penalty
- Initial $6374.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i): All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve. On or about August 23, 2017, a Painter employee's full-face tight-fitting respirator with organic/particulate filter cartridges was stored in a box without being cleaned prior to storage which did not protect the respirator from contamination and dust. The Spirit Metal Fab LLC (previously Spirit Implement LLC) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(h)(2)(i), which was contained in OSHA inspection number 1079291, citation number 1, item number 1f and was affirmed as a final order on December 10, 2015, with respect to a workplace located at 1850 Godfrey Drive, Waupaca, WI 54981.
Recent events (2)
- — I (R) $4500
- — Z (R) $6374
More inspections in this industry (NAICS 333111)
DONALSONVILLE, GA—2026-07-14
LEWIS M. CARTER MANUFACTURING COMPANY, INC.
MARATHON, NY—2026-07-14
AUTOMATED BIOMASS SYSTEMS LLC
EPHRATA, PA—2026-06-12
BLUE RIDGE SILO LLC
NORWOOD YOUNG AMERICA, MN—2026-06-09
111380 - PVS SACKETT-WACONIA INC
FARIBAULT, MN—2026-05-28
111336 - ENVIRONMENTAL TILLAGE SYSTEMS INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342571445.