CLAREMONT, NH —
OSHA Inspection: NORTH COUNTRY SMOKEHOUSE
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of NORTH COUNTRY SMOKEHOUSE in 19 SYD CLARK DRIVE, CLAREMONT, NH 03743 (NAICS 238210). OSHA activity number 342609062.
Where did this inspection happen?
- Establishment
- NORTH COUNTRY SMOKEHOUSE
- Site address
- 19 SYD CLARK DRIVE
- City
- CLAREMONT
- State
- NH
- ZIP
- 03743
- Mailing
- 471 SULLIVAN STREET, CLAREMONT, NH 03743
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.416 A03
- Issued
- Penalty
- Initial $8873.00 · Current $4437.00 Reduced
General-duty citation text
29 CFR 1926.416(a)(3): Before work was begun the employer did not ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit; the employer did not post and maintain proper warning signs where such a circuit existed; and the employer did not advise employees of the location of such lines, the hazards involved, and the protective measures to be taken: Jobsite - Employees were exposed to an electrical hazard when they began work in a 480 volt electrical sub-panel without testing for live power.
Recent events (2)
- — I (S) $4436.5
- — Z (S) $8873
1926.417 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.417(b): Equipment or circuits that were de-energized did not have tags attached at all points where such equipment or circuits could be energized: Jobsite - The locked out circuits on the 480 volt switch gear were not tagged.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1051 A
- Issued
- Penalty
- Initial $7605.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. Jobsite - A stairway or ladder was not provided at all personnel points of access as required from the mezzanine to the top of the coolers.
Recent events (2)
- — I (O) $0
- — Z (S) $7605
More inspections at NORTH COUNTRY SMOKEHOUSE
CLAREMONT, NH—1988-05-18 00:00:00
NORTH COUNTRY SMOKEHOUSE
View NORTH COUNTRY SMOKEHOUSE's full OSHA safety record →
More inspections in this industry (NAICS 238210)
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
KAHULUI, HI—2026-07-16 00:00:00
RISING SUN SOLAR ELECTRIC LLC
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15 00:00:00
EDGE ELECTRICAL SYSTEMS, LLC
More inspections in NH
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
HUDSON, NH—2026-07-16 00:00:00
OMNI COMPONENTS CORP.
NEW BOSTON, NH—2026-07-16 00:00:00
ANDREW GRANT'S TREE SERVICE
PORTSMOUTH, NH—2026-07-15 00:00:00
RODAS CONSTRUCTION CORP
DOVER, NH—2026-07-15 00:00:00
KNOX MARSH DEVELOPMENT LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342609062.