Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KUSTOM MACHINING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KUSTOM MACHINING LLC in 850 BOWLING LANE, WAUPACA, WI 54981 (NAICS 332710). OSHA activity number 342651668.

Watch Kustom Machining LLC — free Get an email when a new federal OSHA severe-injury report for Kustom Machining LLC is published. One employer, no account, unsubscribe in one click.
Site address
850 BOWLING LANE
City
WAUPACA
State
WI
ZIP
54981
Mailing
PO BOX 313, WAUPACA, WI 54981
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.:    On or about September 21, 2017 the sliding doors on the front and both sides of the Milltronics Centurion 6 CNC were not affixed and/or interlocked to ensure the doors were in the closed position while the machine was running.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1910.303 C03 I

Deleted Serious Gravity 5 4 instances 4 exposed
Issued
Penalty
Initial $2173.00 · Current $0.00 Reduced
29 CFR 1910.303(c)(3)(i): Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:   On or about September 21, 2017 the electrical conductors spliced between two milling machines in the Production Area, were not protected and/or insulated sufficiently.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2173

1910.305 B01 I

Deleted Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed:  On or about September 21, 2017 electrical wires entering the main electrical panel on the back of the Milltronics Centurion 6 CNC were not protected from abrasion and/or guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342651668.