OSHA Inspection: GUTTER BOY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GUTTER BOY, INC. in 209 CAMBRIDGE ST., NEW CASTLE, PA 16105 (NAICS 238390). OSHA activity number 342686375.

Watch Gutter BOY, INC. — free Get an email when a new federal OSHA severe-injury report for Gutter BOY, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GUTTER BOY, INC.
Site address
209 CAMBRIDGE ST.
City
NEW CASTLE
State
PA
ZIP
16105
Mailing
4711 W STATE ST., EDINBURG, PA 16116
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:   a) jobsite, 209 Cambridge Street in New Castle, PA.  On or about October 5, 2017, employees working on the roof of the apartment building, 20 feet above the ground, were not utilizing fall protection.
Recent events (1)
  • — Z (S) $3803

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a) jobsite, 209 Cambridge Street in New Castle, PA.  On or about October 5, 2017, the employees working on the roof, 20 feet above the ground, were not trained by the employer to recognize fall hazards and the procedures to minimize fall hazards.
Recent events (1)
  • — Z (S) $3803

1926.503 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written certification record:   a) jobsite, 209 Cambridge Street in New Castle, PA.  On or about October 5, 2017, the employer did not have written certification to verify that the employees who were working 20 feet above the lower level had fall protection training in accordance with paragraph (a) of this section.