Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAXWELL CHASE TECHNOLOGIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAXWELL CHASE TECHNOLOGIES, LLC in 125 WESTLAKE PARKWAY SUITE 100, ATLANTA, GA 30336 (NAICS 326150). OSHA activity number 342718186.

Watch Maxwell Chase Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Maxwell Chase Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
125 WESTLAKE PARKWAY SUITE 100
City
ATLANTA
State
GA
ZIP
30336
Mailing
125 WESTLAKE PARKWAY SUITE 100, ATLANTA, GA 30336
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
43
Ownership type
A

2 citations on file for this inspection.

1910.242 B

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $6338.00 · Current $3803.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 psi.:  At each production machine in the production area - On October 20, 1017 employees were exposed to stuck by hazards in that the pressure at the nozzle outlet used to clean the machines exceeded the measurement capacity of the gauge at 60 psi.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.134 K06

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a)  Entire facility - On or about October 20, 2017 and at times prior, employees were exposed to respiratory hazards in that they were provided Gerson 1730 disposable N-95 two strap respirators to use on a volunteer basis and were not provided the information contained in Appendix D of the respiratory protection standart.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342718186.