ADAIRSVILLE, GA —
OSHA Inspection: LG HAUSYS AMERICA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LG HAUSYS AMERICA, INC. in 310 LG DRIVE SE, ADAIRSVILLE, GA 30103 (NAICS 327991). OSHA activity number 342739521.
Where did this inspection happen?
- Establishment
- LG HAUSYS AMERICA, INC.
- Site address
- 310 LG DRIVE SE
- City
- ADAIRSVILLE
- State
- GA
- ZIP
- 30103
- Mailing
- 310 LG DRIVE SE, ADAIRSVILLE, GA 30103
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 600
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.28 B03 V B
- Issued
- Penalty
- Initial $6097.00 · Current $3658.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(v)(B): Each employee was not protected from falling through a chute-floor hole by a removable guardrail system and toe-boards on not more than two sides of the hole and a fixed guardrail system on all other exposed sides. a) Production Area- Outside of Viatera I Ring Mixing Room: On or before October 10, 2017, and at times prior, the employer exposed employees to fall hazards, in that the employer did not provide a covering to keep employees from falling onto the next lower level through an unguarded chute-floor hole opening.
Recent events (2)
- — I (S) $3658.2
- — Z (S) $6097
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $12934.00 · Current $7760.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) Production Area- Viatera I Ring Mixing Room - On or before October 10, 2017, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not ensure that employees utilized lockout procedures by isolating the electrical energy sources when performing cleaning tasks on the Ring Mixer.
Recent events (2)
- — I (S) $7760.4
- — Z (S) $12934
More inspections at LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2020-10-06 00:00:00
LG HAUSYS AMERICA, INC
ADAIRSVILLE, GA—2019-07-19 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2019-07-19 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2016-10-27 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2014-11-06 00:00:00
LG HAUSYS AMERICA, INC.
View LG HAUSYS AMERICA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327991)
MODESTO, CA—2026-07-13
EXQUISITE STONE DESIGN
CARY, NC—2026-07-09
161507 - ABSOLUTE STONE CORPORATION
PHILADELPHIA, PA—2026-07-09
PHILA FLOORING SUPPLY, LLC
SAINT CLOUD, MN—2026-07-08
111560 - CAPITAL GRANITE AND MARBLE INC
SAINT CLOUD, MN—2026-07-08
111551 - SALZL FLOOR CENTER INC DBA STONE CRAFTERS
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342739521.