ADAIRSVILLE, GA —
OSHA Inspection: LG HAUSYS AMERICA, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LG HAUSYS AMERICA, INC in 310 LG DR SE, ADAIRSVILLE, GA 30103 (NAICS 326191). OSHA activity number 344959614.
Where did this inspection happen?
- Establishment
- LG HAUSYS AMERICA, INC
- Site address
- 310 LG DR SE
- City
- ADAIRSVILLE
- State
- GA
- ZIP
- 30103
- Mailing
- 310 LG DR SE, ADAIRSVILLE, GA 30103
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 300
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 G02 III
- Issued
- Penalty
- Initial $12723.00 · Current $12723.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. By the VT1 main crusher: On or about 10/06/2020, adequate strain relief was not provided on electrical connections at various points of the main crusher. Electrical tape was used in some of the connections while others the had the inner sheaths exposed, thus exposing employees who frequent the area to electrical hazards should the wiring be damaged or ripped out.
Recent events (2)
- — I (S) $12723
- — Z (S) $12723
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $53015.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. LG Hausys at the Viatera plant: On or about 10/22/2020, and at times prior to, annual audits to evaluate the effectiveness of the company's machine specific energy control procedures were not completed as required. Energy sources used at the facility include; but are not limited to, electrical, pneumatic and hydraulic energy and the primary voltage used at the facility includes 480 volts phase 3 60Hz. LG Hausys America Inc, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1416767, citation number 1, item number 2 and was affirmed as a final order on 02/07/2020, with respect to a workplace located at 310 LG Drive SE. ADAIRSVILLE GA, 30103.
Recent events (2)
- — I (R) $0
- — Z (R) $53015
More inspections at LG HAUSYS AMERICA, INC
ADAIRSVILLE, GA—2019-07-19 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2019-07-19 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2017-10-17 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2016-10-27 00:00:00
LG HAUSYS AMERICA, INC.
ADAIRSVILLE, GA—2014-11-06 00:00:00
LG HAUSYS AMERICA, INC.
View LG HAUSYS AMERICA, INC's full OSHA safety record →
More inspections in this industry (NAICS 326191)
BRIDGEVILLE, PA—2026-06-26
KEYSTONE CULTURED SURFACES LLC.
CLEARWATER, FL—2026-05-20
ROYAL BATHS MANUFACTURING COMPANY
DOUBLE SPRINGS, AL—2026-05-08
AMERICAN FIBERGLASS PRODUCTS, INC.
NORTHUMBERLAND, PA—2026-04-03
STRONG INDUSTRIES INC.
LEXINGTON, TN—2026-03-12
BRAVO, INC.
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344959614.