Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEST VIRGINIA COIL MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEST VIRGINIA COIL MANUFACTURING, INC. in 376 MAPLE ACRES ROAD, PRINCETON, WV 24739 (NAICS 334416). OSHA activity number 342799343.

Watch West Virginia Coil Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for West Virginia Coil Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
376 MAPLE ACRES ROAD
City
PRINCETON
State
WV
ZIP
24739
Mailing
376 MAPLE ACRES ROAD, PRINCETON, WV 24739
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334416
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1883.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a)  Skinning Area:  On November 29, 2017 and times prior, employees operated a skinning machine equipped with a Porter Cable dust collector (model #PC400AP) to collect combustible plastic and fiberglass coil skin dust.  The dust had a Kst value of 15.75 bar meters per second.  The dust collector is designed to be used to collect wood material and not designed to be used to collect other combustible dusts, exposing employees to a fire hazard.      (b)  Skinning Area:  On November 29, 2017 and times prior, employees operated a skinning machine equipped with a Delta dust collector (model #50-840) to collect combustible plastic and fiberglass coil skin dust.  The dust had a Kst value of 15.75 bar meters per second.  The dust collector is designed to be used to collect wood material and not designed to be used to collect other combustible dusts, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $1883
  • — Z (S) $2897

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1883.00 Reduced
29 CFR 1910.1200(e)(1):   The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      (a) Skinning Area:  On November 29, 2017 and times prior to, employees generate a combustible dust when skinning the copper coils of plastic and fiberglass skin.  The employer has not developed or implemented a written hazard communication program for employees that are exposed to the combustible dust.        ABATEMENT NOTE:  A written program shall include a description of how the criteria for the following will be met:   1.        Labeling and other forms of warnings;   2.        Safety Data Sheets;   3.        Employee information and training.        Additionally, a list of hazardous chemicals known to be present in the workplace must be compiled.  Methods used to inform employees of the hazards associated with non-routine tasks and the informing of contractors of workplace hazards, including a description of the labeling system used in the facility and the availability of safety data sheets must also be addressed.  The written program must be made available upon request.
Recent events (2)
  • — I (S) $1883
  • — Z (S) $2897

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Skinning Area:  On November 29, 2017 and times prior to, employees generate a combustible dust when skinning the copper coils of plastic and fiberglass skin.  The employer has not provided employees with training on the hazards of the combustible dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

UNKNOWN