GERMANTOWN, WI ·
OSHA Inspection: TCI, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TCI, LLC. in W132 N10611 GRANT DRIVE, GERMANTOWN, WI 53022 (NAICS 334416). OSHA activity number 348606203.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TCI, LLC.
- Site address
- W132 N10611 GRANT DRIVE
- City
- GERMANTOWN
- State
- WI
- ZIP
- 53022
- Mailing
- W132 N10611 GRANT DR, GERMANTOWN, WI 53022
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334416
- Employees
- 197
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 26, 2026
- Abate by
- Jun 22, 2026
- Penalty
- Initial $14,895 · Current $8,937 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about November 20, 2026, the employer did not ensure that the Winder #1 ULTI- M.E.T. (model no. 400, serial no. 97387) was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (b) On or about November 20, 2026, the employer did not ensure that Winder #2 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (c) On or about November 20, 2026, the employer did not ensure that Winder #3 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (d) On or about November 20, 2026, the employer did not ensure that Winder #4 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (e) On or about November 20, 2026, the employer did not ensure that Winder #5 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (f) On or about November 20, 2026, the employer did not ensure that Winder #6 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (g) On or about November 20, 2026, the employer did not ensure that Winder #7 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (h) On or about November 20, 2026, the employer did not ensure that Winder #8 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (i) On or about November 20, 2026, the employer did not ensure that Winder #9 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (j) On or about November 20, 2026, the employer did not ensure that Winder #12 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-1) was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard. (k) On or about November 20, 2026, the employer did not ensure that Winder #13 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-2)was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.
Recent events (2)
- · I (S) $8937
- · Z (S) $14895
1910.212 A03 II
- Issued
- Feb 26, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about November 20, 2026, the employer did not ensure that the Winder #1 ULTI- M.E.T. (model no. 400, serial no. 97387) was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (b) On or about November 20, 2026, the employer did not ensure that Winder #2 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (c) On or about November 20, 2026, the employer did not ensure that Winder #3 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (d) On or about November 20, 2026, the employer did not ensure that Winder #4 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (e) On or about November 20, 2026, the employer did not ensure that Winder #5 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (f) On or about November 20, 2026, the employer did not ensure that Winder #6 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (g) On or about November 20, 2026, the employer did not ensure that Winder #7 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (h) On or about November 20, 2026, the employer did not ensure that Winder #8 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (i) On or about November 20, 2026, the employer did not ensure that Winder #9 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (j) On or about November 20, 2026, the employer did not ensure that Winder #12 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-1) was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard. (k) On or about November 20, 2026, the employer did not ensure that Winder #13 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-2)was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at TCI, LLC.
View TCI, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 334416)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348606203.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.