MONTE VISTA, CO —
OSHA Inspection: THE MONTE VISTA COOPERATIVE ASSOCIATION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE MONTE VISTA COOPERATIVE ASSOCIATION INC. in 2490 E. ROAD 3 NORTH, MONTE VISTA, CO 81144 (NAICS 424510). OSHA activity number 342917978.
Where did this inspection happen?
- Establishment
- THE MONTE VISTA COOPERATIVE ASSOCIATION INC.
- Site address
- 2490 E. ROAD 3 NORTH
- City
- MONTE VISTA
- State
- CO
- ZIP
- 81144
- Mailing
- PO BOX 111, MONTE VISTA, CO 81144
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 16
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.25 B03
- Issued
- Abate by
- Penalty
- Initial $4240.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings: (a) On or about January 29, 2018, and at times prior, workers were exposed to trip and fall hazards on the fixed stairs on the outside of the office building next to the truck scale in that the fifth step of seven, was 9 inches deep while all of the other steps were 12 inches deep. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1000
- — Z (S) $4240
1910.29 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.29(b)(1): A top rail, or equivalent guardrail system member, 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface was not installed: (a) On or about January 29, 2018, and at times prior, the top rail was missing on the platforms affixed to the office building, from which workers take samples of product from trucks that enter the facility. The platforms were approximately 6 feet and 8 feet above the ground. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $4240.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: (a) On or about January 30, 2018, and at times prior, employees were exposed to electrical hazards from a junction box which had a open hole after conduit had been removed from the middle of the bottom. The junction box is located next to the south leg of the grain elevator, and is accessible from the first level of the catwalk and while climbing the fixed fixed ladder of the elevator. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $4240
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $1000.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) On or about January 29, 2018, and at times prior, employees were exposed to electrical hazards in that the employer did not ensure that the electrical panels powering the operations of the ground storage elevator were labeled with the specific purpose of each panel. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $0
1910.305 J02 V
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed): (a) On or about January 29, 2018, employees were exposed to electrical hazards from an outlet box which was missing the receptacle cover. The box is located outside next to the ground storage elevator, and is used to plug in diesel motors during cold weather conditions. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $4240.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet: (a) On or about January 29, 2017, and at times prior, the employer did not include an identifier related to the chemicals on the chemical inventory so that readers can cross reference each listed chemical with it's SDS. Additionally, not all of the chemicals on site were listed in the chemical inventory. The missing chemicals included, but were not limited to: Diesel fuel (flammable; cancer; chemical pneumonitis; pulmonary edema/hemorrhage; skin defatting and drying) Extended Life Universal 50/50 Antifreeze/Coolant Premix (oral acute toxicity; eye irritation) +22deg F Splash Windshield Washer Fluid (flammable; oral, dermal and inhalation acute toxicity) Winter Care RV Antifreeze (flammable) Blue Sky Diesel Exhaust Fluid (skin irritation; serious eye irritation; respiratory irritation) Pesticides (poisonous) Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $4240
1910.1200 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $2120.00
General-duty citation text
29 CFR 1910.1200(f)(6): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with either the information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) On or about January 29, 2017, and at times prior, the employer did not ensure that containers of hazardous chemicals had labels to inform employees about hazards of the chemicals in the containers. Hazardous chemicals in the inadequately labeled containers that employees worked with included: diesel fuel (flammable; cancer; chemical pneumonitis; pulmonary edema/hemorrhage; skin defatting and drying) Extended Life Universal 50/50 Antifreeze/Coolant Premix (oral acute toxicity; eye irritation) +22deg F Splash Windshield Washer Fluid (flammable; oral, dermal and inhalation acute toxicity) Winter Care RV Antifreeze (flammable) Blue Sky Diesel Exhaust Fluid (skin irritation; serious eye irritation; respiratory irritation) Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2120
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) On or about January 29, 2018, and at times prior, the hazard communications program did not include an explanation of the label elements for containers of hazardous chemicals, nor the order of information on safety data sheets. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about January 29, 2018, and at times prior, the employer did not ensure that employees were safe from hazardous energy by conducting annual inspection of each energy control procedure in use at the facility. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). Abatement Note: The periodic inspection shall be performed by an authorized employee other than the ones(s) utilizing the energy control procedure, for the purpose of correcting any deviations or inadequacies identified. The periodic inspection shall include a review of each authorized and affected employees' responsibilities under the procedure. The employer shall certify the periodic inspections by identifying the machine or equipment on which the procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at THE MONTE VISTA COOPERATIVE ASSOCIATION INC.
MONTE VISTA, CO—2011-12-07 00:00:00
THE MONTE VISTA COOPERATIVE ASSOCIATION INC.
View THE MONTE VISTA COOPERATIVE ASSOCIATION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424510)
POMEROY, WA—2026-07-01
WA317991893 - POMEROY GRAIN GROWERS INC
EDISON, NE—2026-06-30
AG VALLEY COOP
SCIO, OR—2026-06-10
317744473 - BEACON SEED LLC
HEALY, KS—2026-05-29
BARTLETT GRAIN CO
GOODLAND, KS—2026-05-28
THE SCOULAR COMPANY - GOODLAND
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342917978.