OSHA Inspection: METROPOLITAN MINISTRIES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of METROPOLITAN MINISTRIES in 2009 NORTH FLORIDA AVE, TAMPA, FL 33602 (NAICS 624221). OSHA activity number 343040010.

Watch Metropolitan Ministries — free Get an email when a new federal OSHA severe-injury report for Metropolitan Ministries is published. One employer, no account, unsubscribe in one click.
Site address
2009 NORTH FLORIDA AVE
City
TAMPA
State
FL
ZIP
33602
Mailing
2001 NORTH FLORIDA AVE, TAMPA, FL 33602
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
624221
Employees
5
Ownership type
A

9 citations on file for this inspection.

1910.36 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8315.00 · Current $4989.00 Reduced
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency.   a)  For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. Employees had only one exit route in the event of an emergency.
Recent events (2)
  • — I (S) $4989
  • — Z (S) $8315

1910.36 E02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(e)(2): The door that connects any room to an exit route did not swing out in the direction of exit travel when the room is designed to be occupied by more than 50 people or if the room is a high hazard area:  a)  For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. The door connecting to the single exit route swung into the room that was used for storage of combustible and flammable materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 G04

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the 28 inches minimum width requirements for exit routes:  a)  For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. The objects that protruded into the exit route reduced the width in areas to a minimum of 10.5 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6652.00 · Current $3991.00 Reduced
29 CFR 1910.176(b): Storage was not secure. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.  a)  For employees working at 2009 North Florida Avenue in Tampa, in the main front storage room, on or about March 22, 2018. The material was stacked in unstable piles while the employees were working exposing the employees to a struck by hazard.
Recent events (2)
  • — I (S) $3991.2
  • — Z (S) $6652

1910.176 C

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:  a)  For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. The storage areas contained tripping hazards in that the materials were stored in the path of the walking and exit routes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $6652.00 · Current $3991.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) For employees working at 2009 North Florida Avenue in Tampa, on or about March 22, 2018. At the main power panel that housed the breakers for the electrical components installed in the building, two unused circuit breakers were missing covers, exposing the energized main bus bar.  b) For employees working at 2009 North Florida Avenue in Tampa, on or about March 22, 2018. In the rear area storage an outlet box and a junction box did not have the unused knockout openings closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $3991.2
  • — Z (S) $6652

1910.305 B02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   a) For employees working at 2009 North Florida Avenue in Tampa, on or about March 22, 2018. In the rear area storage an outlet box did not have a faceplate.   b) For employees working at 2009 North Florida Avenue in Tampa, on or about March 22, 2018. In the rear area storage two junction boxes were missing the cover plates.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B08 I

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $933.00 · Current $560.00 Reduced
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted.  a) For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. An electrical box was not attached to the wall and was hanging by the wiring. The wiring brought the box from approximately 8 feet above the ground to approximately 5 feet above the ground for employee use.
Recent events (2)
  • — I (O) $559.8
  • — Z (O) $933

1910.305 A02 IX

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:  a)  For employees working at 2009 North Florida Avenue in Tampa, in the rear area storage room, on or about March 22, 2018. The lamps in the rear storage area did not have covers on them to protect them from contact or breakage. The lights were the only illumination for this room and had to be turned on and off by pull strings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

WEINGART