ELYRIA, OH —
OSHA Inspection: METRO DESIGN, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of METRO DESIGN, INC. in 10740 MIDDLE AVENUE, ELYRIA, OH 44035 (NAICS 332710). OSHA activity number 343045589.
Where did this inspection happen?
- Establishment
- METRO DESIGN, INC.
- Site address
- 10740 MIDDLE AVENUE
- City
- ELYRIA
- State
- OH
- ZIP
- 44035
- Mailing
- 10740 MIDDLE AVENUE, ELYRIA, OH 44035
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 16
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, the employer did not ensure that employees who setup and maintain the Prodigy CNC lathes such as, but not limited to, machine numbers 6, 10, and 27, were trained in the skills required for the safe application, usage, and removal of energy controls. Employees who changed tooling and set indicators were not trained to isolate and/or render energy sources safe.
Recent events (2)
- — I (S) $3000
- — Z (S) $3696
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees were exposed to rotating parts and pinch point hazards in that the #6 Prodigy CNC lathe (s/n 20-4128-S) was not deenergized prior to set-up and servicing tasks such as, but not limited to, tooling changes. The employer did not ensure that energy control application steps were implemented to control hazardous electrical/mechanical and pneumatic energy prior to the servicing tasks the employer did not: - Ensure employees had the method or means to control hazardous energy. - Ensure that equipment was turned off or shut down. - Physically operate energy isolating devices to control the energy source(s). - Verify that isolation and de-energization of the machine or equipment had been accomplished. b. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees were exposed to rotating parts and pinch point hazards in that the #27 Prodigy CNC lathe (s/n s/n 20-4320-S) was not deenergized prior to set-up and servicing tasks such as, but not limited to, tooling changes. The employer did not ensure that energy control application steps were implemented to control hazardous electrical/mechanical and pneumatic energy prior to the servicing tasks the employer did not: - Ensure employees had the method or means to control hazardous energy. - Ensure that equipment was turned off or shut down. - Physically operate energy isolating devices to control the energy source(s). - Verify that isolation and de-energization of the machine or equipment had been accomplished. c. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees were exposed to rotating parts and pinch point hazards in that the #10 Prodigy CNC lathe (s/n 20-4187-S) was not deenergized prior to set-up and servicing tasks such as, but not limited to, setting indicators and tooling changes. The employer did not ensure that energy control application steps were implemented to control hazardous electrical/mechanical and pneumatic energy prior to the servicing tasks - the employer did not: - Ensure employees had the method or means to control hazardous energy. - Ensure that equipment was turned off or shut down. - Physically operate energy isolating devices to control the energy source(s). - Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $3696
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $4560.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees operating the Topper vertical CNC lathe (s/n 011251) were exposed to injuries from the machine's rotating parts, point of operation, and/or flying chips. The machine was not adequately guarded in that employees were not prevented from accessing the hazard area during operation. b. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees operating the Upgrade Technologies machine #2 located in the back room were exposed to injury from the machine's rotating parts, point of operation, and/or flying chips. The machine was not adequately guarded in that employees were not prevented from accessing the hazard areas during operation. c. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees operating the #9 Prodigy CNC lathe (s/n 20-4186-S) located in the back room were exposed to injuries from the machine's rotating parts, point of operation, and/or flying chips. The machine was not adequately guarded in that employees were not prevented from accessing the hazard areas during operation. d. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees operating the #6 Prodigy CNC lathe (s/n 20-4128-S) located in the front room were exposed to injuries from the machine's rotating parts, point of operation, and/or flying chips. The machine was not adequately guarded in that employees were not prevented from accessing the hazard areas during operation. e. Metro Design, Inc. - Elyria, Ohio: On or about March 27, 2018, employees operating the #27 Prodigy CNC lathe (s/n 20-4320-S) located in the front room were exposed to injuries from the machine's rotating parts, point of operation, and/or flying chips. The machine was not adequately guarded in that employees were not prevented from accessing the hazard areas during operation.
Recent events (2)
- — I (S) $4560
- — Z (S) $5174
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16 00:00:00
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16 00:00:00
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16 00:00:00
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15 00:00:00
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15 00:00:00
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343045589.